FILTER TIMES (Factory settings: 08.00 to 09.00)
By pressing the OK key you can select up to five filter times per day, when the water will
be channelled via the overflow. This is necessary since the water level is only controlled in
the collection tank and not in the pool.
CAUTION: You must circulate the water via the overflow for at least 30 to 60 minutes per
day. Only in this way can you measure and control the water level (the measurement
takes place in the overflow tank).
Additionally, the correct water flow (via the overflow channel) will be re-established by
entering the times for the overflow operation, which will ensure proper circulation within
the pool. With public pools, we recommend switching to over-flow operation between
one and two hours before the pool is occupied in order to ensure the correct water flow.
CAUTION (Warranty exclusion)
Damage which is caused by too low a water level (e.g. burnt-out solar cover) will not be
covered by us.
CANCELING FILTER TIMES: by pressing the OK key, all filter times can be cancelled.
During this process you will be asked to confirm whether you really mean to cancel all
filter times. You confirm by pressing the OK key.
FROST PROTECTION: (factory setting OFF)
By pressing the OK key the frost protection can be selected as ON or OFF by means of
the arrow keys. In the ON position you can select by means of the OK key at which tem-
perature (-50 °C to +20 °C) the frost protection switches on the filter pump. The adjustable
hysteresis (temperature difference between ON and OFF) gives the switch-off signal.
Additionally a collective alarm can be interconnected. If you have a heating system connec-
ted you can select at which pool water temperature the heating should switch on and off.
6
AS Control Plus
By pressing the MODE key you enter the menu.
The additional functions are indicated in the menu with the ➔ Symbol.
MENU LANGUAGE:
Press the OK key and you can then select by means of the arrow key
between German, French, Italian, English and Spanish..
FILTER PUMP MENU
OVERLOAD PROTECTION: (factory setting is OFF)
Press the OK key and you are then in the overload protection menu
where you can first select if the overload protection is to be switched
on or off. If the OP is switched on, by pressing the OK key the motor
current will be measured, displayed and saved for the connected pump.
If you decide to connect a different pump to the AS Control Plus, you
will need to determine the current for the new pump. You can exit the
display of the current by pressing the MODE key. Once you have deter-
mined the current, you can select the tolerance level to determine the
percentage overload at which the overload protection is triggered and
the filter pump switches off (typically the tolerance is set to 15 %).
If the contact of the flow switch opens, the pump stops after a delay of
20 seconds.

HEATING MENU:

SET VALUE: (factory setting 25 °C)
By pressing the OK key the set point of the water temperature can be
selected by means of the arrow keys between 1 °C and 40 °C.
Shortcut: Press the Filter button for 4 seconds to start a backwash
02-2019 EN
(factory setting is German