CPG 351IDCPG38M Посібник користувача - Сторінка 6
Переглянути онлайн або завантажити pdf Посібник користувача для Діапазони CPG 351IDCPG38M. CPG 351IDCPG38M 10 сторінок. Induction range
User Manual
Drop-In Model Installation
•
Countertop thickness must not exceed 2" .
•
Drop-in models should only be installed by professionals .
1 . Ensure the installation location has proper ventilation . There must be at least 7" of available space under the
mounted induction range, and the inside temperature of the cabinet must not exceed 90°F .
2 . Drop-in models feature remote control . The control panel will be mounted separately for easy access .
3 . Use and place the provided template in the intended installation location, allowing at least 4" of countertop space
on each side . Cut the countertop using the template and cutout dimensions illustrated . (Fig . 1)
4 . Insert the induction range into the cutout and apply a thin layer of silicone sealant around the surface .
5 . Repeat similar instructions for the control panel . Center the control panel to the induction range whenever possible .
6 . Connect the control panel cable to the induction range .
FIG. 1
B
C
1
C
C
6
FRONT
2
4
TOP
2
4
A
B
3
C
.
A Max . 2"
Countertop Depth
Min . 7"
B
Cabinet Clearance
Min . 4"
C
Countertop Clearance
12 .99"
1
Range Cutout Height
12 .2"
2
Range Cutout Width
2 .87"
3
Controller Cutout Height
6 .1"
4
Controller Cutout Width
www.cookingperformancegroup.com