These units are designed for commercial use and not for household use .
Installation must conform to all applicable codes . Improper installation will void the
manufacturer's warranty .
Do not obstruct or reduce the air flow rate of the natural ventilation openings on the
oven or the vent located at the rear of the oven .
Discontinue use if power cord or electrical wires are frayed or worn .
This product conforms to UL-197 standards and is required to be installed under a
ventilation hood in accordance with all applicable codes .
Combustiable Clearance Requirements: 20" Sides, 28" Back
Non-Combustiable Clearance Requirements: 2" Sides, 2" Back
Installation Instructions
The place of installation must be indoors, well ventilated, and the ambient temperature must be at least
40 degrees Fahrenheit . The unit is required to have at least 2" of clearance on the sides and back from
non-combustible surfaces, or at least 20" and 28" of clearance on the sides and back, respectfully, from
combustible surfaces . Ensure that all four legs are installed correctly before the operation of this oven .
The unit is required to be installed on a non-combustible surface with 4" legs, or a combustible floor with
a stand . For full-size models, level unit by adjusting the (4) feet which have an adjustment of 1¾" for
accurate leveling .
This product conforms to UL-197 standards and requires it to be
under an exhaust hood . A vertical distance of not less than 48"
shall be provided between the top of the appliance and filters
or any other combustible material . Exhaust installation must
conform to applicable local codes .
Do not obstruct or reduce the air flow rate of the natural
ventilation openings on the oven or the vent located at the rear
of the oven . To ensure proper ventilation and clearance, the
provided spacer is required to be installed .
The spacer must be installed by screwing (2) self-threading
screws on the back of the unit immediately below the cooling
fan.
NOTE:
For Oven Stacking Instructions, please see page 14.
WARNING:
DO NOT OBSTRUCT THE VENT OR COOLING FAN LOCATED AT THE REAR OF
THE OVEN.