Allied Telesis 86222-10 Примітки до випуску - Сторінка 6
Переглянути онлайн або завантажити pdf Примітки до випуску для Програмне забезпечення Allied Telesis 86222-10. Allied Telesis 86222-10 14 сторінок. Patch for rapier switches and ar800 series modular switching routers
6
PCR: 01213
Module: TRG, SNMP
The Trigger Facility was generating a trap with variable { 0 0 }, and was not
documented in the ATI enterprise MIB. This issue has been resolved. The
MIB object triggerLastTriggerActivated ({ enterprises(1) alliedTelesyn(207)
mibObjects(8) brouterMib(4) atrouter(4) modules(4) trigger(53) 1 }) has been
defined, to record the trigger number of the last trigger activated, and this
variable is now transmitted in the trigger activation trap triggerTrap.
PCR: 01214
Module: SWI
In a Rapier G6, fitted with a fibre uplink module with all ports active,
switching traffic between port 1 and the uplink caused the traffic flow to
cease after a period of time depending on the volume of traffic. This issue
has been resolved.
PCR: 01216
Module: STP
The Rapier did not include the message age of the received BDPU message
in the message age of the BDPU it transmitted. Also, the message age of the
message transmitted BDPU could be less than that of the received BDPU,
which contravenes IEEE 802.3d. This issue has been resolved.
PCR: 01219
Module: VLAN,SWI
Reception of incorrectly tagged packets was causing corruption of the ARL
table, eventually causing the switch to lock up. This issue has been resolved.
Tagged packets with invalid VLAN identifiers are now discarded. The
INFILTERING parameter of the SET SWITCH PORT command now
defaults to ON.
PCR: 01221
Module: SWI
Flow control performance has been improved.
PCR: 01225
Module: IPSEC
The IPsec SA ID now wraps correctly at the 16 bit (ID = 65535) boundary.
The ID is also checked to verify that it is free before it is used.
PCR: 01227
Module: PPP
If PPPoE AC services were not deleted in the same order they were added,
the DELETE command would return an " operation successful" message
but the service would still appear in the output of the SHOW PPP PPPOE
command. This issued has been resolved.
PCR: 01229
Module: SWI
The CREATE CONFIG command did not include all required L3FILTER
parameters in the generated script file.
PCR: 01232
Module: SWI
The L3 table on the Rapier G6 is now cleared when a switch port goes down
to ensure the L3 and ARP tables are consistent.
Patch Release Note
Network affecting: No
Network affecting: No
Network affecting: No
Network affecting: No
Network affecting: No
Network affecting: No
Network affecting: No
Network affecting: No
Network affecting: No
Patch 86222-10 for Software Release 2.2.2
C613-10319-00 REV J