Dell PowerEdge 4350 Посібник з оновлення - Сторінка 9
Переглянути онлайн або завантажити pdf Посібник з оновлення для Сервер Dell PowerEdge 4350. Dell PowerEdge 4350 24 сторінки. Dell poweredge 4350 system upgrade installation guide
Також для Dell PowerEdge 4350: Встановлення в стійку (35 сторінок), Посібник з оновлення (23 сторінок), Посібник з монтажу (34 сторінок), Посібник користувача (35 сторінок)
support.dell.com
3.
Remove and replace the guide brackets.
See "Removing and Replacing the Guide Brackets", found later in this
document.
4.
Remove the cooling shroud.
See "Removing and Replacing the Cooling Shroud", found later in this
document.
5.
Install the upgrade microprocessor.
See "Installing the Upgrade Microprocessors", found later in this document.
6.
Replace the cooling shroud.
See "Removing and Replacing the Cooling Shroud", found later in this
document.
If the upgrade kit comes with a new cooling shroud, you must install the new
cooling shroud. See "Installing a New Cooling Shroud", found later in this
document.
7.
Reassemble and check the system, as follows:
a.
Rotate the power supply back into position, making sure that the securing
tab snaps into place.
b.
Replace the covers and front bezel. Reconnect your computer and peripher-
als to their power sources and turn them on.
As the system boots, it detects the presence of the new microprocessor
and automatically changes the system configuration information in the Sys-
tem Setup program.
NOTE: After you remove and replace the cover of a PowerEdge 1300 system,
the chassis intrusion detector causes the following message to be displayed at
the next system start-up:
ALERT! Cover was previously removed.
c.
Enter the System Setup program and confirm that the top line in the system
data area correctly identifies the installed microprocessor(s). By default, the
serial numbers of Pentium III microprocessors are not displayed. See the
procedures in "Using the System Setup Program" in your User's Guide for
accessing and modifying entries in the System Setup screens.
d.
Reset the chassis intrusion detector while in the System Setup program by
changing Chassis Intrusion to Not Detected.
NOTE: If a setup password has been assigned by someone else, contact your
network administrator for information on resetting the chassis intrusion detector.
Dell PowerEdge Systems — Microprocessor Upgrade
1-5