Allied Telesis AT-9800 Series Примітка до випуску - Сторінка 4

Переглянути онлайн або завантажити pdf Примітка до випуску для Програмне забезпечення Allied Telesis AT-9800 Series. Allied Telesis AT-9800 Series 5 сторінок. How to set up pppoe between a linux client and access concentrator
Також для Allied Telesis AT-9800 Series: Як налаштувати (9 сторінок), Посібник зі швидкого встановлення (12 сторінок), Як це зробити (8 сторінок)

Allied Telesis AT-9800 Series Примітка до випуску
4
Features in sb273-01
CR00007417
Module: ATM,ENCO
Previously, when the packet overhead limits were exceeded, some packets
were being silently dropped by SQoS.
This issue has been resolved.
Additionally, extra checking has been added to the ATM process so that it
will explicitly drop, and count, any packets that still exceed the overhead
limit. This will aid in the diagnosing of any other cases where packets are
being dropped. (No PCR number.)
CR00007428
Module: ETH
The AR026 4-port Ethernet PIC was not capable of receiving 1519-1522 byte
VLAN-tagged packets. Instead, these packets were dropped because they
were considered too long.
Also, some early revisions of the AR720 and AR740 were not capable of
receiving 1519-1522 byte VLAN-tagged packets.
These issues have been resolved. (PCR number: 50065)
CR00007436
Module: L2TP
When the router was acting as an L2TP Access Concentrator (LAC) it would
fail to negotiate a Virtual tunnel to another vendor's LNS. This was due to
invalid Proxy LCP AVPs being used within the ICCN message.
This issue has been resolved. (No PCR number.)
CR00007770
Module: SWI
On 9800 series switches with GBICs installed, if a GBIC with an active link
was physically removed the interface would not go DOWN.
This issue has been resolved. (No PCR number.)
CR00008127
Module: SWI
When hot-swapping a Switch Blade line card, the trunking information on
other line cards could get over-written and cause the switch to stop
forwarding traffic.
This issue has been resolved. (No PCR number.)
Level 3
CR00006086
Module: x25t
IP interfaces over X25 were not operating correctly.
resolved. (No PCR number.)
CR00007476
Module: IPG
The DNS relay has been changed to allow the relay of resource record types
between 0x1d and 0xff. Previously packets with these types of resource
records were dropped.
This issue has been resolved (No PCR number.)
Software Maintenance Release Note
Level: 2
Level: 2
Level: 2
Level: 2
Level: 2
Level: 3
This issue has been
Level: 3
C613-10436-00 Rev A
Release sb273-01