Boot error message for missing SD card
The XC730-16G system has only one SD card. When you start the system, the following error message is displayed:
The secondary SD card is missing, not responding, or in write-protected mode. Do one of the
following:
1.
Install an SD card media in the secondary SD card slot.
2.
Reseat or replace the SD card media.
3.
If the secondary SD card is intentionally not installed or write-protected mode is
expected, then no response is required.
The message is a known issue and you must ignore it.
Deployment outline
The flow of tasks in deploying the XC Series Web-Scale Converged Appliance is shown here.
Figure 4. Deployment workflow process.
First time boot scripts for VMware vSphere
Run the VMware vSphere first boot scripts on every node after they are properly racked and cabled. The first time boot scripts
accomplish the following tasks:
NOTE: These first time boot scripts run automatically upon the first boot of the system and include multiple reboots.
•
Creates vSwitch Nutanix, internal and external port groups and vmkernal interface with address on internal portgroup.
•
Activates vMotion and management on the default external vmkernel interface (vmk0).
•
Enables TSM-SSH and TSM and allows sshClient, nfsClient, and ntpClient through the firewall.
•
Denies vprobeServer through the firewall.
•
Sets advanced ESXi parameters.
•
Enables auto-start, sets the default RAM, and number of vCPU for the CVM.
•
Elects applicable data-disk storage controller for PCI pass-through.
•
Disables drivers associated with pass-through storage controllers.
•
Installs the following VIBs: Nutanix VAAI, updated ixgbe and igb driver, and GPU VIBs (if applicable).
•
Renames local VMFS datastore to standard naming convention: NTNX-local-ds-<block id>-<node_position>.
•
Starts CVM and check for the existence of /tmp/svm_boot_succeeded.
•
Restarts host.
First time boot scripts for Microsoft Hyper-V
Complete the Micorsoft Hyper-V First boot scripts on every node after they are properly racked and cabled. The first time boot
scripts accomplish the following tasks:
NOTE: These first time boot scripts are run from a first time boot scripts wizard and require minimal user intervention.
11