Allied Telesis CONVERTEON AT-CM2K0S Технічний паспорт - Сторінка 2

Переглянути онлайн або завантажити pdf Технічний паспорт для Програмне забезпечення Allied Telesis CONVERTEON AT-CM2K0S. Allied Telesis CONVERTEON AT-CM2K0S 2 сторінки. Converteon series line card
Також для Allied Telesis CONVERTEON AT-CM2K0S: Посібник з монтажу (3 сторінок), Технічний паспорт (3 сторінок)

Allied Telesis CONVERTEON AT-CM2K0S Технічний паспорт
| Converteon Series Line Card
AT -CM2K0S
Technical Specifications
Status Indicators
System LEDs
LED
Color
Description
RDY
Green The line card has passed diagnostics
Off
The line card has not passed
diagnostics
ML
Green MissingLink mode is enabled
Off
MissingLink mode is disabled
SML
Green Smart MissingLink mode is enabled
Off
Smart MissingLink mode is disabled
OAM
Green OAM mode is enabled
Off
OAM mode is disabled
Port LEDs
10M copper port speed is implied when
both 100M or 1000M are OFF
LED
Color
Description
LK
Green Link established on the port
Off
No link established on the port
AT
Green TX/RX activity detected on the port
Off
No activity detected on the port
DUP
Green Copper port operating in full-duplex
mode
Off
Copper port operating in half-duplex
mode
100M Green Copper port operating at 100Mbps
Off
Copper port not operating at 100Mbps
1000M Green Copper port operating at 1Gigabit
Off
Copper port not operating 1Gigabit

DIP Switches

The AT-CM2K0S line card features DIP switches to
enable/disable the OAM mode.
Table 1. Diagnostic Mode DIP Switches Positions
Operating Mode DIP 1 DIP 2 DIP 3 DIP 4
Link Test (default)
Off
Off
Smart MissingLink
Off
On
(SML)
MissingLink (ML)
Off
Off
OAM Bypass
On
Off
OAM Visible
On
On
'X' means the DIP switch position could be either On or Off.
USA Headquarters
|
19800 North Creek Parkway
European Headquarters
|
Via Motta 24
Asia-Pacific Headquarters
|
11 Tai Seng Link
www.alliedtelesis.com
© 2007 Allied Telesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.
Connectors and Pinouts
10/100/1000T Ethernet Port
Connector RJ-45
Pinout
Auto MDI/MDI-X
SFP
Fiber optic, Gigabit Ethernet
Ethernet Specifications
MAC address table
Maximum packet size

Physical Specifications

Dimensions:
(W x D x H)
Weight:
Power Characteristics
Power consumption

Environmental Specifications

Maximum operating temperature: 0°C to 40°C
Maximum storage temperature:
Operating and storage altitude:
Relative humidity operating:
Relative Humidity Storage:
Predicted MTBF (Telcordia SR332): 880,000 hrs
Standards
EMI part 15:
FCC class A, EN55022 class A, VCCI class A, C-Tick, CE
Off
X
Immunity:
On
X
EN55024
On
X
Safety:
Off
X
UL60950-1 (cULUS), EN60950-1 (TUV)
Off
X
Electrical Interfaces:
ITU-T G.703
ANSI T1.403
ITU-T G.823
AT&T TR62411
|
Suite 200
|
Bothell
|
6830 Chiasso
|
Switzerland
|
Singapore
|
534182
|
8K
1632 bytes
2.2cm x 7.3cm x 13.0cm
(0.78" x 2.89" x 5.1")
0.54 kg (1.20 lbs)
6.8W max
(32°F to 104°F)
-25°C to 70°C
(-13°F to 158°F)
Up to 3,048 meters
(10,000 feet)
5% to 90%
non-condensing
5% to 95%
non-condensing
|
WA 98011
|
USA
|
T: +1 800 424 4284
|
T: +41 91 69769.00
|
F: +41 91 69769.11
T: +65 6383 3832
|
F: +65 6383 3830

Ordering Information

AT-CM2K0S
10/100/1000T to SFP Converteon line card
Related Products
AT-CV1000-xx
One slot Converteon chassis
AT-CV1203-xx
Two slot Converteon chassis
AT-CV5000-xx
18 slot, Converteon chassis
AT-SPxx series
Small Form Pluggable optical modules
|
F: +1 425 481 3895
617-000199 RevE