Some of the issues addressed in this Release Note include a level number. This
number reflects the importance of the issue that has been resolved. For details
on level numbers, please contact your authorised distributor or reseller.
Features in SB251-08
Patch SB251-08 includes all issues resolved and enhancements released in
previous patches for Software Release 2.5.1, and the following enhancements:
PCR: 03251
Module: SWI
A fatal error occurred when the ADD SWITCH TRUNK command specified
an invalid port. This issue has been resolved.
PCR: 03414
Module: SWI
A fatal error occurred when removing a line card from a SwitchBlade if STP
was enabled. This issue has been resolved.
PCR: 03466
Module: SWI
System performance was low when adding large numbers of entries to
CAM. This issue has been resolved. CAM is now initialised to allow better
performance, especially for the addition of ARP and IP entries.
PCR: 03470
Module: SWI
The DELETE SWITCH TRUNK PORT command could cause an unrelated
port to stop forwarding packets, or learn new MAC addresses. This issue
has been resolved so that unrelated ports are not affected by the trunk group
port deletion.
PCR: 03509
Module: SWI
All IP routes were being added to all switch instances. This caused issues on
SwitchBlade line cards that did not have enough CAM to store the routes,
and the line card did not always need every route. IP routes are now only
added:
to a switch instance if the route was learned on that instance
if the route is for an interface
if the route was added statically, or
if the switch instance has a CAM which is the same size or larger than
the CAM of the switch instance that the route was learned on.
PCR: 03518
Module: SWI
An issue exists where the CAM entry 0 in the VLAN Tag table is either not
updated or is being overwritten with invalid data. This PCR adds
debugging to trace the fault.