Two refrigerant lines must be run from inside the compressor unit cabinet to the Desuperheater.
The available holes (marked "plugged") in the cabinet for the SC compressor units are shown in
Figure 4.
For the CC compressor unit, shown in Figure 5, two additional holes of at least 1" diameter are to
be field drilled in the plumbed panel of the cabinet to accommodate the interconnecting refrigerant
tubing.
See Kit Contents in Desuperheater Electrical Installation section.
Desuperheater piping and connections to the compressor units are illustrated as follows:
SC: Figures 6 & 7
CC: Figures 8 & 9
Water piping for all compressor unit sizes is 1/2" OD copper with insulation on both water lines and
the storage water heater located as close as practical to the Desuperheater, within 25 feet
maximum.
Figures 1 and 2 illustrate typical water piping, fittings and connections for the Desuperheater and
storage water heater.