DHD 52/MX Посібник з монтажу - Сторінка 8
Переглянути онлайн або завантажити pdf Посібник з монтажу для Музичний мікшер DHD 52/MX. DHD 52/MX 20 сторінок. Series 52
4
Environmental Specifications
In the following you can find some general advices concerning the environment of an 52/MX. If these values and
standards are not adhered, DHD can not assure the proper functionality of the device.
operating temperature: +5 ... +35° Celsius
relative humidity:
5
Assembling and Wiring the Hardware
In the following you can find information on the mechanical assembling and wiring of an 52/MX Mixing Console and how to
integrate it into a mixing system.
5.1
Wiring the Console
At first you have to keep in mind that it is possible to arrange an 52/MX Mixing Console with a lot of different shapes and
sizes. Because of that it is not possible to explain the wiring process in detail for every mechanical assembly, but the basic
structure is always quite the same.
Here is the way how to wire the exemplary console in the picture below.
1. Normally, the 52-4050 Console Controller modules are already mounted in the console frame. If not so, you have to do
this first.
2. Mount the PoE switches in the console frame or put them into the shipped wall mount housings and install these
housings close to the console frame. Within this flow of work, connect the red and blue power supply flat connectors of
the PoE switches with each other and at least one of them with an outward speakon jack. (See the red cables in the
picture below.)
Specifications and design are subject to change without notice. The content of this document is for information only. The information presented in this document does not form part
of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use.
Publication thereof does neither convey nor imply any license under patent rights or other industrial or intellectual property rights.
Warning
Make sure the device has the operating temperature before switching it on. Also,
the relative humidity must not be exceeded. Above all, no humidity must
condense on or in the device!
20 ... 85%, non condensing
Note
Please note the environmental specifications of the RM4200D DSP Frame, which
is connected to the 52/MX Mixing Console. Information on that can be found in
the RM4200D system reference guide.
Warning
Avoid damaging components by electrostatic discharge (ESD).
Before you touch or mount electronical components, make sure you do not carry
any electrostatic charges. Earth yourself using a grounded metal object (heater,
rack) to divert electrostatic charges immediately before you touch electronical
components.
Environmental Specifications
Version 1.10.0 - 17.03.2010
6