System diagnostics and indicator codes
This section describes the diagnostic indicators on the system front panel that displays the system status during system startup.
The following sections contain information about the chassis LEDs and indicator codes of VxRail E660 Series.
Status LED indicators
NOTE:
The indicators display solid amber if any error occurs.
Icon
Description
Drive indicator
Temperature
indicator
Electrical
indicator
Memory indicator The indicator turns solid amber if a
PCIe indicator
Condition
The indicator turns solid amber if
there is a drive error.
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
temperature is out of range or
there is a fan failure).
The indicator turns solid amber
if the system experiences an
electrical error (for example,
voltage out of range, or a failed
power supply unit (PSU) or
voltage regulator).
memory error occurs.
The indicator turns solid amber if a
PCIe card experiences an error.
Corrective action
● Check the System Event Log to determine if the
drive has an error.
● Run the appropriate Online Diagnostics test.
Restart the system and run embedded
diagnostics (ePSA).
● If the drives are configured in a RAID array,
restart the system, and enter the host adapter
configuration utility program.
Ensure that none of the following conditions exist:
● A cooling fan has been removed or has failed.
● System cover, air shrouds, or back filler bracket
has been removed.
● Ambient temperature is too high.
● External airflow is obstructed.
If the problem persists, see the
Check the System Event Log or system messages
for the specific issue. If it is due to a problem with
the PSU, check the LED on the PSU. Reseat the
PSU.
If the problem persists, see the
Check the System Event Log or system messages
for the location of the failed memory. Reseat the
memory module.
If the problem persists, see the
Restart the system. Update any required drivers for
the PCIe card. Reinstall the card.
System diagnostics and indicator codes
6
Support
section.
Support
section.
Support
section.
27