Dell PowerConnect 2624 Посібник користувача - Сторінка 17

Переглянути онлайн або завантажити pdf Посібник користувача для Перемикач Dell PowerConnect 2624. Dell PowerConnect 2624 38 сторінок. Powerconnect 26 series
Також для Dell PowerConnect 2624: Посібник користувача (21 сторінок)

Dell PowerConnect 2624 Посібник користувача
Table 2-1. Basic Troubleshooting
Problem
Link LED is lighted, but the
activity (ACT) LED does not
blink.
Link LED is lighted and the
FDX/HDX LED blinks
occasionally.
Link LED is lighted and the
FDX/HDX LED blinks frequently.
(continued)
Probable Cause
There is no Ethernet traffic on the
link. The LED blinks only when
traffic is being passed to or sent
from a device that is connected to
the port.
The attached device is not
configured correctly.
This can be normal link activity.
Some collisions take place during
normal operation.
Mismatched duplex mode.
The link is reaching its maximum
capacity.
Corrective Action
No action required.
Verify that the port or NIC on the
attached device is operating
properly.
No action required.
Ensure that any devices
connected to the switch are set to
automatically detect and set port
speed and duplex settings.
Resegment the network to
decrease the number of users on
the link.
Troubleshooting
17