Dell PowerConnect J-EX8208 Посібник із швидкого старту - Сторінка 2
Переглянути онлайн або завантажити pdf Посібник із швидкого старту для Перемикач Dell PowerConnect J-EX8208. Dell PowerConnect J-EX8208 24 сторінки. Powerconnect j-series
Part 4: Perform Initial Configuration
NOTE: Before you begin the configuration, enable a DHCP client on the management
PC you connect to the switch, so that the switch can obtain an IP address dynamically.
NOTE: Read the following steps before you begin the configuration. Complete the initial
configuration using EZSetup within 10 minutes. The LCD panel displays a count-down
timer when the switch is in initial setup mode. The switch exits EZSetup after 10 minutes
and reverts to the factory configuration, and the PC loses connectivity to the switch.
1. Transition the switch into initial setup mode using the Menu and Enter buttons to the
right of the LCD panel. To do this:
− Press Menu until you see MAINTENANCE MENU. Then press Enter.
− Press Menu until you see ENTER EZSetup. Then press Enter.
If EZSetup does not appear as an option in the menu, select Factory Default to return
the switch to the factory default configuration. EZSetup is displayed in the menu only
when the switch is set to the factory default configuration.
− Press Enter to confirm setup and continue with EZSetup.
2. Connect the Ethernet cable from the Ethernet port on the PC to the MGMT port on
the SRE module that is in slot SRE0.
The interface (the port labeled MGMT on the SRE module in slot SRE0) is now
configured as the DHCP server with the default IP address, 192.168.1.1. The switch
can assign an IP address to the management PC in the range 192.168.1.2 through
192.168.1.253.
3. From the PC, open a Web browser, type
press the Enter key.
4. On the J-Web login page, enter root as the username, leave the password field
blank, and click Login.
5. On the Introduction page, click Next.
6. On the Basic Settings page, enter the hostname, enter and reenter a password,
specify the time zone, and synchronize the switch date and time settings with the
management PC or set them manually.
7. Click Next.
8. On the Management Options page select Out-of-band Management—Configure
management port to configure the management interface.
9. Click Next.
10. Specify the IP address and default gateway for the management interface.
11. Click Next.
12. On the Manage Access page, you may select options to enable Telnet, SSH, and
SNMP services. For SNMP, you can configure the read community, location, and
contact.
13. Click Next. The Summary page displays the settings you have selected.
14. Click Finish. The configuration is committed as the active switch configuration. You
can now log in with the CLI or the J-Web interface to continue configuring the switch.
NOTE: After the configuration is committed, the connectivity between the PC and the
switch might be lost. To reconnect, release and renew the IP address by executing the
appropriate commands on the PC or by removing and reinserting the Ethernet cable.
Information in this document is subject to change without notice. Trademarks used in this text: Dell™, the DELL™ logo, and PowerConnect™ are trademarks of Dell Inc. Juniper Networks® and Junos® are registered trademarks of
Juniper Networks, Inc. in the United States and other countries. All other trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners. Juniper Networks assumes no
responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice. Products made or sold by Juniper Networks or components thereof
might be covered by one or more of the following patents that are owned by or licensed to Juniper Networks: U.S. Patent Nos. 5,473,599, 5,905,725, 5,909,440, 6,192,051, 6,333,650, 6,359,479, 6,406,312, 6,429,706, 6,459,579,
6,493,347, 6,538,518, 6,538,899, 6,552,918, 6,567,902, 6,578,186, and 6,590,785.
Copyright © 2010, Juniper Networks, Inc. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Juniper Networks is strictly forbidden. Printed in USA.
Juniper Networks Part Number: 530-036263. Revision 01, 15 August 2010
in the address field and
http://192.168.1.1
.
Safety Warnings Summary
This is a summary of safety warnings. For a complete list of warnings, including
translations, see the PowerConnect J-EX8208 switch documentation at
.
http://www.support.dell.com/manuals
WARNING: Failure to observe these safety warnings can result in personal injury
or death.
Permit only trained and qualified personnel to install or replace switch components.
Perform only the procedures described here and the J-EX8208 switch documentation.
Other services must be performed only by authorized service personnel.
Before installing the switch, read the planning instructions in the J-EX8208 switch
documentation to make sure that the site meets power, environmental, and clearance
requirements for the switch.
Before connecting the switch to a power source, read the installation instructions in the
J-EX8208 switch documentation.
The weight of a J-EX8208 switch chassis with just the backplane is approximately
89 lb (41 kg). A base configuration switch weighs 149 lb (68 kg). A redundant
configuration switch weighs 187 lb (85 kg). When fully loaded, the switch weighs
284 lb (130 kg). We strongly recommend that you use a mechanical lift to install the
unit in a rack or cabinet. If you attempt to manually install the chassis, the rack must be
open and clear on all sides to allow full access. Remove all components from the
chassis, and have three people lift and position the switch on the mounting brackets.
To prevent injury, keep your back straight and lift with your legs, not your back.
If the rack has stabilizing devices, install them in the rack before mounting or servicing
the switch in the rack.
The switch is pluggable type A equipment installed in a restricted-access location. It
has a separate protective earthing terminal provided on the chassis. This separate
protective earthing terminal must be permanently connected to earth ground for
installations that require a separate grounding connector to the chassis.
Before installing or after removing an electrical component, always place it
component-side up on a flat antistatic surface or in an antistatic bag.
Do not work on the switch or connect or disconnect cables during electrical storms.
Before working on equipment that is connected to power lines, remove jewelry,
including rings, necklaces, and watches. Metal objects heat up when connected to
power and ground and can cause serious burns or become welded to the terminals.
Power Cable Warning (Japanese)
The power cable is only for this product. Do not use this cable for another product.
Contacting Dell Inc.
For technical support, see
http://www.support.dell.com
.