Allied Vision MANTA Посібник - Сторінка 16

Переглянути онлайн або завантажити pdf Посібник для Цифрова камера Allied Vision MANTA. Allied Vision MANTA 18 сторінок.

9.5. Reassembling Prosilica GT Large Format housing cameras
1. Position sensor unit (a) and lens mount (c), so that markers (b) align.
2. Fit the sensor unit (a) into the lens mount (c).
3. Put one drop of Loctite 290 threadlocker on the threads of the two M2 x 10 socket head cap screws (d).
Insert screws and spacers (d) and tighten screws at a maximum torque of 3.5 lbf-in (0.4 Nm).
Figure 29: Inserting the two M2 x 10 socket head cap screws
4. Flip the front assembly (g) back to the body assembly (h) to approximately 45°.
5. Engage the flexible contact bar (f) to the mating contact bar.
6. Avoid bending or squeezing the ribbon cable (e):
Flip the front assembly (g) back to the body assembly (h) and close the camera.
Camera top
Figure 30: Rejoining the front assembly with the body assembly
a
b
Figure 28: Fitting the sensor unit into the lens mount
d
e
h
Page 16 of 18
Preparing Cameras without
Sensor Cover Glass
c
f
g