Cleaning and care
Leave the door on the unclean side ajar
after cleaning to allow the machine to dry.
The filters in the water inlet valves (1) and in
the inlet hoses (2) should be checked from
time to time for soiling and cleaned if
necessary.
Drum bearings
Once the service interval has been reached
the following message will appear in the
display:
Lubricate drum bearings
§
Call the Service Department.
Press the A"Back" button to clear the
message from the display. This message will
appear in the display each time you switch
the machine on until the service work has
been carried out by the Miele service
technician.
,
Disconnect the machine from the
mains supply.
38
Before lubricating the drum bearings the
venting screw must be unscrewed. The
grease nipples on the left and right hand
drum bearings must be lubricated after
approx. 1000 operating hours with Arcanol
L 100. While lubricating, rotate the drum
three times. Wipe away any old lubricant.
A