Miele G 1202 Посібник - Сторінка 15
Переглянути онлайн або завантажити pdf Посібник для Посудомийна машина Miele G 1202. Miele G 1202 46 сторінок.
Також для Miele G 1202: Посібник (14 сторінок)
G 1xxx/G 2xxx
Function
Appliance width setting
Appliance height setting
Model setting
Country setting
Table 8: Service Programming Mode, G 1262
1
If the electronic needs to be replaced during servicing, the following steps must be taken
during programming: In the first step, set the country specification and model, then switch
off the appliance. Repeat access and then set appliance width and height, and the
appropriate supply water hardness.
2
If the dishwasher is connected to an external ion exchanger water softener (i.e. that
needs to be regenerated with salt), the water hardness delivered by the system must be
set. If this value is unknown, set to 8°d (8.6 grains per gallon).
3
The SER country specification includes the following countries: Portugal, France, the
Netherlands, Belgium and Great Britain.
Save and quit:
Switch off the appliance.
Programming
Press the Tab button 35x.
The "Tab" LED flashes 3x
slowly and 5x rapidly
1
intermittently. Press the
Program button as
appropriate to make the
desired setting.
Press the Tab button 36x.
The "Tab" LED flashes 3x
slowly and 6x rapidly
1
intermittently. Press the
Program button as
appropriate to make the
desired setting.
Press the Tab button 38x.
The "Tab" LED flashes 3x
slowly and 8x rapidly
1
intermittently. Press the
Program button as
appropriate to make the
desired setting.
Press the Tab button 39x.
The "Tab" LED flashes 3x
slowly and 9x rapidly
1
intermittently. Press the
Program button as
appropriate to make the
desired setting.
15
Technical Information
Display
The display shows p and a digit
alternately. Setting options: p0 =
24" (60cm); p1 = 18" (45cm).
The display shows p and a digit
alternately. Setting options:
p0 = Normal machine height (G
1xxx); p1 = XXL model (G 2xxx).
The "Rinse" LED is off or flashes.
The display shows p and a digit
alternately. Individual setting
possibilities depend on model and
whether a circulation pump with
slide shutter (WAW), sensor
softener (SEH), and/or salt
container in door (SIT) are fitted.
Appropriate setting: p1 = G1262,
(w/out WAW, w/out SEH, w/out
SIT).
The "Rinse" LED is off or flashes.
The display shows p and a digit
alternately. The following
countries can be set: p1 = EUR
(Europe); p2 = AUS (Australia);
p3 = USA, p4 = JPN (Japan),
p5 = I/E (Italy/Spain), p6 = SER
3
(Southern Europe).