Miele PG 8172 ECO Інструкція з експлуатації Посібник з експлуатації - Сторінка 35
Переглянути онлайн або завантажити pdf Інструкція з експлуатації Посібник з експлуатації для Посудомийна машина Miele PG 8172 ECO. Miele PG 8172 ECO 42 сторінки. Commercial dishwashers
Electrical connection
16.4 Connecting the drain hose
The drain hose may not be shortened or damaged.
Do not bend the drain hose when laying it.
Caution
The drain hose is located in the machine.
INFO
The machine is equipped with a drain pump. The on-site water drain must have a trap. The
maximum height of the on-site water drain is 650 mm.
Back view
17 Electrical connection
Danger to life: Live components!
The machine and the relevant additional devices must be connected by an electrical
company authorised by the relevant electricity supplier as per the locally applicable
Danger
standards and regulations.
When performing installation and maintenance work, disconnect the machine from the pow-
er network. Check that there is no voltage.
The electrical safety of this machine is guaranteed only if it is connected to a correctly installed protective
circuit and a residual current circuit breaker. It is very important that this basic safety requirement is
tested and in case of doubt the house installation is checked by a qualified electrician.
The circuit diagram must be observed.
The equipment may only be operated at the voltages and frequencies specified on the data plate.
A fixed connection must as a priority be installed for machines that are delivered without a power cord.
When the machine must be permanently connected (without a plug), a mains disconnector with all-pole
separation from the network must be installed. The mains disconnector switch must have a contact
opening width of at least 3 mm, and must also be lockable in the neutral position.
The electrical connection must be secured as a separately fused circuit with slow fuses or circuit
breakers. The protection depends on the total power consumption of the machine. The total connected
load is specified on the data plate of the machine
In the electric supply line, install a universal current sensitive residual-current circuit breaker class B with
a tripping current of 30 mA (DIN VDE 0664) as a frequency inverter is located in the machine.
Machines delivered from the factory equipped with mains cable and safety plug (single phase), or CEE
plug are (triple phase), may only be connected to the mains network indicated on the data plate.
74
Connect the drain pipe (A) to the machine.
Connect the drain pipe to the on-site water drain.