4. Remote control learning
4. Remote control learning
4.1 Learning of one transmitter
The 1st memorized key performs the STEP by STEP function (opening and closing of the gate), the 2
th
performs the OPEN function, 4
The control unit exits from the learning phase if no new key or trasnmitter command is given in 10 seconds.
Make sure that the board is out of any
1
menus, press the button UP[+]
Press one key of the transmitter
2
If you want to memorize another key or a new
transmitter repeat the procedure
4.2 Learning with the hidden key of an already memorized transmitter
With the hidden key of a transmitter it is possible to enter the learning phase in order to memorize new keys or new transmitters.
With the automation still, with the aid of a clip press the hidden button of an already memorized transmitter, the flashing light lights on, now it is
possible to memorize new keys or transmitters.
4.3 Cancellation of one transmitter
Enter the learning phase with the UP[+] button or with the hidden key of a memorized transmitter (see 5.1 or 5.2).
Press in the same time the hidden key and 1
The flashing light bilnks 4 times and on the display will appear
5. Setting the wing stroke
For a correct functioning of the system, it is absolutely indispensable the use of mechanical stops in opening and closing.
5.1 Easy settings of the wings stroke (parameter LsI
Connect to the MOTOR 1 output the wing which beats.Install an aventual electrical lock on this wing. MOTOR 1 is always activated first during
opening phase and in second during closing phase. In this procedure it is necessary to provide the limits positions of the wings with a step by step
command (SS).
Unlock the motors, move the wings in the middle of the
1
stroke and relock the motors.
Press and keep pressed the buttons UP[+] e MENU
for at least 5 seconds.
2
When the wing 1 reaches the opening mechanical
stop give a step by step command (SS)
3
When the wing 2 reaches the opening mechanical stop
4
give a step by step command (SS)
When the wing 2 reaches the closing mechanical stop
5
give a step by step command (SS)
When the wing 1 reaches the closing mechanical stop
6
give a step by step command (SS)
When the wing 1 reaches the the opening mechanical
7
stop give a step by step command (SS)
When the wing 2 reaches the the opening mechanical
stop give a step by step command (SS)
8
Warning: in case of intervention of a safety device, the learning is stopped and will appear on the display the written
Press Step by Step key to start again the learning from the 2
6-1622176
rev.05
01/03/2019
key performs the CLOSE function.
st
key of the transmitter that you want to cancel.
nd
point.
ITA
On the display will appear
and the flashing light lights on
On the display will appear don
If the transmitter was already
memorized will appear Fnd
After 2 seconds the display will show the
memory location of the memorized transmitter,
for example
LsI
LsI ≠ P P P P )
LsI
The wing 1 moves in opening.
If the wing moves in closing press the DOWN[-]
button to stop and reverse the direction of
movement and give a step by step command
(SS) to resume the procedure
The wing 1 stops and the wing 2 moves in
opening.
If the wing moves in closing press the DOWN[-]
button to stop and reverse the direction of
movement and give a step by step command
(SS) to resume the procedure
Wing 2 stops, after 2 seconds the wing 2 moves
in closing
Wing 2 stops, after 2 seconds the wing 1 moves
in closing
Wing 1 stops, after 2 seconds the wing 1 moves
in opening
Wing 1 stops, after 2 seconds the wing 2 moves
in opening
Wing 2 stops, after 2 seconds the gate closes
with the settings of delay between the wings and
slowing downs set in the menu. When the gate is
closed the learning phase is ended.
ENG
FRA
ESP
DEU
POR
nd
key performs the partial opening, the 3
don.
don
don
Fnd.
Fnd
Fnd
rd
key