Allmatic CT INVERTER AM Посібник з монтажу - Сторінка 11
Переглянути онлайн або завантажити pdf Посібник з монтажу для Блок управління Allmatic CT INVERTER AM. Allmatic CT INVERTER AM 12 сторінок. Programmable control board for sliding gates with inverter technology
9 Tips for a successful installation
9.1 High speed movements
PROBLEM
The motor stops for the effort during the movements
It is easy to stop the automation during the movements
counteracting the movement
The gate moves slowly despite having set an high speed
The motor stops and the control unit shows FAULT on the
display or 10 seconds of fast blinking
9.1 Low speed movements (slowing down)
PROBLEM
The motor stops for the effort during the movements
It is easy to stop the automation during the movements
counteracting the movement
The gate moves slowly despite having set an high speed
9.3 Correct working
The correct setting of parameter is when you are not able to stop the automation when trying counteracting the movement.
The use of safety devices is absolutely necessary to ensure the safety of the automation.
6-1622595
rev.06
13/01/2017
Raise the torque supplied to the motor until problem is solved
High Torque OP, High Torque OP
Lower the speed of the motor until problem is solved
High Speed OP, High Speed CL
Lower the torque supplied to the motor until problem is solved High Tor-
que OP, High Torque OP
Lower the speed of the motor until problem is solved
High Speed OP, High Speed CL
Raise the torque supplied to the motor until problem is solved
Low Torque OP, Low Torque CL
Lower the speed of the motor until problem is solved
Low Speed OP, Low Speed CL
ITA
ENG
FRA
ESP
DEU
POR
SOLUTION
SOLUTION
11 / 12