Functioning of the auxiliary light
OFF: functioning of courtesy light: the light activates further a command and stays
lit for all the motion period, going off after a time set by the function .

ON:
functioning light zone, the light activates at the beginning of the motion.
The counting of the switching off time set by the function  starts once
that the gate reaches the position of complete closing.
Switching off of the auxiliary light.

The time of the switching off of the auxiliary light can be set from 1 second till 300
seconds.
Clock time.
OFF: disabled function

ON:
enabling the function a time relay can be connected ( free contact timer) at
the input open.
The function is disabled in case the dead man function is enabled.

5. Faults diagnostics

The control unit indicates anomalies or malfunctions of the system through a message that appears on the display of the control unit.
In particular the faults are codified as follows:
Fault intervention motor protector. The control unit has detected an absorption higher than the one set by the menu (see entry 

of paragraph 4.3) for a period longer than 3 seconds. Check that ther are not anomalies in the system. In case that there are
problems in the installation, increase the threshold of the motor protector being careful to not overpass the absorption values of given
by the motor's constructor.
Fault lack of phase (only wiht three-phase functioning). The control unit has detected an unbalancing between the phases higher

than 40%.
Fault of motor thermal. To use the automation again leave the motor still until the alarm ceases.

Power supply
Photocells power supply
Acessories power supply
Motor output
Flashing light output
Courtesy light output
Auxiliary function output ( only with card R1).
Dry contact output, NOT powered.
6-1622598
REV.3
23/09/2020
DESCRIPTION
TECHNICAL FEATURES - CT3IND CONTROL UNIT
230 Vac +-10%, 50Hz singlephase / 400 Vac 50Hz Three-phase
24 Vdc 3W MAX
24 Vac 3W MAX
230Vac single phase 800W Max, 400 Vac THREE-PHASE 1,5KW Max (current limited to
10A), cos > 0.8
230 Vac 60W MAX for fix light , without self blinking
230Vac 100W MAX
230Vac 5A Max, 30Vdc 5A Max
ITA
ENG
SELECTABLE VALUES
FRA
ESP
DEU
POR
DEFAULT
min-max
ON — OFF
OFF
1 (s) — 300 (s)
60 (s)
ON — OFF
OFF