Miele DA 217 Інструкція з експлуатації Посібник з експлуатації - Сторінка 15
Переглянути онлайн або завантажити pdf Інструкція з експлуатації Посібник з експлуатації для Вентиляційна витяжка Miele DA 217. Miele DA 217 36 сторінок. Cooker
Altering the filter operating
hours counter
You can match the maximum time for
the operating hours counter to the type
of cooking you do.
Select a short time if you roast or fry a
lot.
Grease filters
The operating hours counter for the
grease filters is set at 30 hours. This
time can be lengthened or shortened.
You can choose from 20, 30, 40 or 50
hours.
Use the On/Off touch control to
switch the fan off.
Press the run-on option touch control
and the grease filter touch control at
the same time.
The indicator lamps for the grease filter
touch control and the _touch con-
trol will flash.
Use the _to select the required
time.
The _touch control indicator lamps
show the time which has been set:
1st lamp from left = 20 hours
2nd lamp from left = 30 hours
3rd lamp from left = 40 hours
4th lamp from left = 50 hours
Confirm the procedure by pressing
the grease filter touch control.
If the procedure is not confirmed
within 4 minutes of programming
the steps, the cooker hood will auto-
matically revert to the "old" data.
Active charcoal filter
The active charcoal filter is used when
the cooker hood is operated in recircu-
lation mode. It is not required for the air
extraction mode.
The cooker hood is set at the factory
for extraction mode, on delivery the
operating hours counter for the active
charcoal filter is set to "unlimited".
Resetting the charcoal filter operating
hours counter is only necessary if the
cooker hood is to be used in recircula-
tion mode:
Use the On/Off touch control to
switch the fan off.
Press the run-on option touch control
and the charcoal filter touch control
at the same time.
The control lamps for the charcoal filter
touch control and the _ touch con-
trol will flash.
Use the _to select the required
time.
The _ touch control indicator lamps
show the time which has been set:
1st lamp from left = 120 hours
2nd lamp from left = 180 hours
3rd lamp from left = 240 hours
4th lamp from left = unlimited
(only for air extraction mode)
Confirm the procedure by pressing
the grease filter touch control.
If the procedure is not confirmed
within 4 minutes of programming
the steps, the cooker hood will auto-
matically revert to the "old" data.
Operation
15