Miele DA 449-4 Посібник з експлуатації та встановлення - Сторінка 6
Переглянути онлайн або завантажити pdf Посібник з експлуатації та встановлення для Вентиляційна витяжка Miele DA 449-4. Miele DA 449-4 40 сторінок. Cooker
The grease filters should be
regularly cleaned or changed as
appropriate. Saturated filters are a fire
hazard. See "Cleaning and care".
Do not use a steam-cleaner to
clean this appliance. Pressurised
steam could reach the electrical
components and cause a short circuit.
The appliance is only intended for
use by adults who have read these
instructions. This appliance is not a toy!
To avoid the risk of injury, keep children
well away, and do not allow them to
play with it or use the controls. They will
not understand the potential dangers
posed by it. They should be supervised
whenever you are working in the
kitchen.
Older children may use the
appliance only when its operation
has been clearly explained to them and
they are able to use it safely,
recognising the dangers of misuse.
Please be aware that on
appliances with halogen lighting,
the lamps will get very hot during use
and remain hot for some time after
switching off. To safeguard against
burning, keep children well away from
the lamps at all times.
Packaging, e.g. cling film, polystyrene
and plastic wrappings, must be kept
out of the reach of babies and young
children. Danger of suffocation.
Dispose of or recycle all packaging
safely as soon as possible.
6
The minimum safety distance
between the top of a cooker or hob
and the bottom of the cooker hood is as
follows, unless a greater distance is
specified by the manufacturer of your
cooking appliance:
– 450 mm above electric hobs
and cookers,
– 650 mm above gas hobs and
cookers,
– 650 mm above an open grill or deep
fat fryer.
If more than one appliance is fitted
beneath the cooker hood and they have
different minimum safety distances to
the cooker hood, select the greater
distance.
Safety regulations prohibit the
fitting of a cooker hood over solid
fuel stoves.
All ducting, pipework and fittings
must be of non-flammable material.
These can be obtained from the Miele
Spare Parts department or from
builders' merchants.
The appliance must not be
connected to a chimney or vent
flue which is in use. Neither should it be
connected to ducting which ventilates
rooms with fireplaces.
If exhaust air is to be extracted into
a chimney or ventilation duct no
longer used for other purposes, seek
professional advice.