OPEN INPUT
11-15
Connect the button OPEN between the clamps 11 and 15 of the
terminal board.
12-15
CLOSE INPUT
Connect the button CLOSE between the clamps 12 and 15 of
the terminal board.
13-15
PARTIAL OPENING INPUT
Connect the PARTIAL OPENING button (PED.) between the
clamps 13 and 15 of the terminal board.
14-15
STEP BY STEP INPUT
Connect the STEP-BY-STEP BUTTON (S.S.) between the clamps
14 and 15.
MOTOR OUTPUT
Connect the three phases of the motor in the terminals 16-17-
18 (M2)
WARNING!! THE MOTOR MUST BE CONNECTED AS
16-17-18
TRIANGLE / DELTA MODE Δ
Only for stand alone connection
For the connection of the motor we recommend to use a
screened cables 3 poles + earth 1.5 mm2 (type FD781CY)
COURTESY LIGHT
Connect the courtesy light to the clamps 19 and 20, 230Vac
19-20
100W MAX.
FLASHING LIGHT
21-22
Connect the flashing light to the clamps 21 and 22 [M2].
23
Ground connection
POWER SUPPLY
Connect the power supply cable between the terminals 24
24-25
and 25.
Use a cable with an adequate section based on the current
absorbed by the motor
ELECTRICAL BRAKE / ELECTRICAL LOCK power supply
Connect the ELECTRICAL BRAKE / ELECTRICAL LOCK between
26-27-28
the terminals 26-27 if needs of normally closed dry contact
(16A MAX)
Connector
ENCODER INPUT
Connect the encoder to the control unit on the specific
E
connector
6 / 20
ATTENTION: leave it open if not used
ATTENTION: leave it open if not used
ATTENTION: leave it open if not use
Under the dead man mode the STEP BY STEP BUTTON operates
as OPEN.
ATTENTION: leave it open if not used
Before activating the automation make sure that all the safey
devices are correctly cabled and functioning, refer to the
preliminary checkings
WARNING! Risk of electric shock
It is possible to light up the action area of the
automatism during each motion.
The functioning of the auxiliary light is controlled by the MENU
A [P1].
Use a flashing light without self flashing card 230Vac 60W MAX
Do not connect the card directly to the electric network. Put a
device which can ensure the disconnection of each pole from
the power supply of the control unit.
The activation / deactivation of the encoder functions is mana-
ged in the MENU A