Installation
Electrical connection
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
All electrical work should be
performed by a qualified electrician
in strict accordance with national
regulations (for USA: ANSI-NFPA 70)
and local safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous.
Ensure that power to the appliance is
OFF while installation or repair work
is performed.
Verify that the voltage, load and
circuit rating information found on
the data plate (located behind the
baffle filters), match the household
electrical supply before installing the
hood.
Use only with ventilation hood cord-
connection kits that have been
investigated and found acceptable
for use with this model hood.
If there is any question concerning
the electrical connection of this
appliance to your power supply,
please consult a licensed electrician
or call Miele's Technical Service
Department.
WARNING: THIS APPLIANCE MUST
BE GROUNDED
40
Grounding Instructions
WARNING - Improper grounding can
result in a risk of electric shock.
This appliance must be grounded. In
the event of an electrical short
circuit, grounding reduces the risk of
electric shock by providing a path of
least resistance.plug.
If there is any doubt, have the
electrical system of the house
checked by a qualified electrician.
To increase security before the
machine is installed, it is
recommended to install a protective
switch (30 mA).
The hood must be hard wired
accordingly:
Black/Red wire: connect to L1 (live)
White wire: connect to N (neutral)
Green wire: connect to GND (ground)
If the unit will be hard wired to the
electricity supply, the wire gauge of the
individual leads must be between 18
AWG and 16 AWG.
The strain relief must be used to ensure
problem-free connection.