4.3 Programming of pulse value and reset of the index.
Press push-button (picture 3) for more than 2s and keep it pressed. A display loop will start(each display appr. 2s). An action (pro-
gramming) will occur, if the push button is released during the actual display.
Display
Display description /
programming action
Battery exchange
(only available in case of battery
disconnection)
Comma position: 0 digits
Comma position: 1 digit
Comma position: 2 digits
Comma position: 3 digits
Programming the meter offset. Flashing digits can be modified by keeping the push button pressed. The selected
value will be memorised by releasing the push bottom. Repeat pressing the push button to return to the program-
ming modus and select the next value on second position or leave the programming modus, as shown in example:
Restore last index before reset. (Only available 5 min after reset!)
4.4 Finishing the installation (picture 4)
•
Close the box cover and fix the front cover with screws to back cover. Stick the
needed label version on the box cover. (Take attention to the chosen unit!)
•
Protect the screws by user seals.
•
Use the inscription field to indicate the meter point (e.g. name of tenant, flat number
etc.)
5. Reset and battery exchange
5
Value-Setting: the index of theTC-E can be adjusted to any value (see 4.3)
Battery exchange (see 4.1): after removing the battery the TC-E will switch to following states:
•
TC-E without power <30s: Index and pulse value will be kept, TC-E will start counting with old settings.
•
TC-E without power >30s but <600s: Index and pulse value will be kept, TC-E will start with a display test (see 4.2) and starts
counting with old settings.
•
TC-E without power >600s: Index and pulse value will be reset to default values, the pulse value has to be programmed.
6. Technical Data
6
Dimensions:
Battery type:
Battery lifetime:
Protection class:
Environment temperature:
Characteristic of pulse emitter:
Min. pulse / pause duration:
Max. pulse frequency:
Ron :
Roff :
Max. bounce time:
Max. cable length:
Allmess GmbH · Am Voßberg 11 · D - 23758 Oldenburg i.H.
Telefon (0 43 61) 625-0 · Telefax (0 43 61) 625-250
E-Mail: [email protected] · www.allmess.de
Zertifiziertes Unternehmen nach DIN EN ISO 9001: 2000
Reg.-Nr. 000468 QM
Pulse value
version for volume
1m
0.1 m
0.01 m
0.001 m
hold
release
width = 64mm; length = 44.5mm; height = 20mm
Lithium SL-360/P – 3.6V – 2.3Ah, Part-No. 10128
approx. 10 years (at 20°C environmental temperature)
IP 64
-15-55°C (Inside installation)
100ms/100ms
5Hz
≤200Ω (resistance during pulse)
≥1MΩ (resistance during intervall)
15ms
30m
mit staatlich anerkannten Prüfstellen:
für Messgeräte für Wasser
3
(= 1000 L)
1 MWh (= 1000 kWh)
3
(= 100 L)
0.1 MWh (= 100 kWh)
3
(= 10 L)
0.01 MWh (= 10 kWh)
3
(= 1 L)
0.001 MWh (= 1 KWh)
hold
release
für Messgeräte für Wärme
Pulse value
version for energy
picture 4