4. AutoLoad Plus will prompt you to select the device type. Select "PlusConnect GatesAir ZXA".
You may optionally change the description for the PlusConnect. The description appears in
AutoLoad Plus to identify each PlusConnect channel.
5. Enter the IP address and port number of the PlusConnect. These should be the same settings
you used when you configured the PlusConnect using telnet.
6. Check the Map default set of channels box if you wish to automatically add the most
commonly used PlusConnect parameters to the ARC Plus (recommended). There must be 24
consecutive unused channels, including this starting channel. You do not need to have
additional Integrated Input Units and Integrated Command Relay Units in order to use these
channels.
Important! PlusConnect channels take the place of normal I/O channels. If a metering input,
status input, or command relay is connected to an ARC Plus channel and a PlusConnect
parameter is subsequently mapped to that channel, the I/O channel will no longer be
displayed.
7. Click OK.
Manually Mapping PlusConnect Parameters
Even if you chose to map the default set of channels when you added the PlusConnect to the site, you
may wish to map additional channels to the ARC Plus. The PlusConnect GatesAir ZX transmitter
provides access to many remote control parameters, all of which are selectable for display on the ARC
Plus (provided there is sufficient unused channel capacity).
PlusConnect™ GatesAir ZXA Installation and Operation Manual
Overriding channels in AutoLoad Plus
7