Miller SUITCASE 12RC Посібник користувача - Сторінка 24

Переглянути онлайн або завантажити pdf Посібник користувача для Зварювальне приладдя Miller SUITCASE 12RC. Miller SUITCASE 12RC 40 сторінок. Wire feeder with gun and meters
Також для Miller SUITCASE 12RC: Технічні характеристики (2 сторінок), Посібник користувача (36 сторінок), Посібник користувача (40 сторінок)

Miller SUITCASE 12RC Посібник користувача

6-3. Setting DIP Switches For Timer Models

DIP SWITCH SETTINGS
Set DIP Switch S1 on PC50 for desired operation.
.
Showing DIP switch setting as
Factory default settings:
OPEN
1
2
3
4
5
Preflow settings:
OPEN
6
1
2
3
4
5
3 Sec Preflow
Burnback settings:
OPEN
6
1
2
3
4
5
Long Burnback
(0.140 Sec)
Postflow settings:
OPEN
6
1
2
3
4
5
5 Sec Postflow
Re­Trigger settings:
OPEN
6
1
2
3
4
5
Re−Trigger Enabled
With Re-Trigger enabled: If trigger is pulled within 3 seconds of trigger release, feeder will skip Preflow and go directly to Weld portion
of the weld sequence. If trigger is pulled after 3 seconds, feeder will go directly to Preflow portion of the weld sequence.
OPERATION
The normal weld sequence for this feeder is: pull trigger, feeder goes into 1.5 seconds of preflow, after preflow feeder will be in weld,
release trigger, feeder will be in 5 seconds of postflow. However, the preflow portion of the sequence will be skipped, if the feeder is
re-triggered within 3 seconds of releasing the trigger. If more than 3 seconds passes before the feeder is re-triggered, the feeder weld
sequence starts with 1.5 seconds of preflow.
OM-263984 Page 20
indicates it has no affect on that particular function.
Ÿ
3 Sec Preflow
Ÿ
No BurnBack
Ÿ
5 Sec Postflow
Ÿ
6
7
8
Re−Trigger Enabled
OPEN
7
8
6
7
8
1
2
3
4
5
1.5 Sec Preflow
OPEN
7
8
6
7
8
1
2
3
4
5
Medium Burnback
(0.110 Sec)
OPEN
7
8
6
7
8
1
2
3
4
5
Postflow Disabled
OPEN
7
8
6
7
8
1
2
3
4
5
Re−Trigger Disabled
OPEN
6
7
8
1
2
3
4
5
1
2
3
0.5 Sec Preflow
Preflow Disabled
OPEN
6
7
8
1
2
3
4
5
1
2
3
Burnback Disabled
Short Burnback
(0.081 Sec)
OPEN
6
7
8
4
5
OPEN
6
7
8
4
5