3. INSTALLATION CONSIDERATIONS: DIMENSIONS & WEIGHTS, MOUNTING & SPACING REQUIREMENTS
Dimensions are in Inches (mm)
CTF 50 A (Without Fan)
CTF 75 A (Without Fan)
CTF 25 A
CTF 40 A
CTF 60 A (Without Fan)
CTF 90 A (Without Fan)
CTF 120 A (With Fan)
2.4 (60.1)
3.1 (80)
0.7 (18.5)
4.1
(104)
0.5 (14.0)
Depth: 5.6 (143)
Weight: 2.1 lbs (970 g)
Depth: 5.6 (143)
Depth: 5.6 (143)
Weight: 2.9 lbs (1,300 g)
Weight: 1.8 lbs (810 g)
Weight: 3.3 lbs (1,500 g)
Rear Panel Mounting Template
Length
Width
Model
In. (mm)
In. (mm)
CTF 25-40-50-60A
4.4 (112)
1.7 (44)
CTF 75-90-120A
4.4 (112)
4.4 (113)
CTF 150-200-250A
11.3 (287)
1.7 (42)
5. GENERAL TECHNICAL DATA & SPECIFICATIONS
LOAD, FIRING, DIAGNOSTICS & RATINGS
AC 51 resistive or low inductance loads
CATEGORY OF USE
AC 55b infrared lamps
(Tab. 2 EN60947-4-3)
AC 56a: transformer loads
PA - Load management by adjusting the firing angle (only
configuration single-phase or delta open)
ZC - Zero Crossing with constant cycle time (settable in range
1-200sec)
Trigger Mode
BF - Burst Firing, or D.O.T. with variable cycle time optimized min.
HSC - Half Single Cycle corresponds to Burst Firing that includes ON
and OFF half-cycles.
Useful for reducing flicker with short-wave IR loads (applied only to
single-phase resistive or 3-phase 6-wire open delta loads).
V, V
2
: Voltage feedback proportional to RMS voltage value on load
(useful to compensate possible variations in line voltage).
I, I
2
: Current feedback: bound to RMS current value on load to com-
Feedback Mode
pensate variations in line voltage and/or variations in load impedance.
P: Power feedback: proportional to real power value on load (useful
to keep constant values of electrical power assigned regardless of
load impedance or line voltage variations).
Max rated voltage
480 Vac
600 Vac
Work voltage range
90 - 530 Vac
90 - 660 Vac
Non-repetitive voltage
1200 Vp
1600 Vp
Rated Frequency
50/60Hz Auto-Synchronization
CTF MODEL
CTF-025 CTF-040 CTF-050 CTF-060 CTF-075 CTF-090 CTF-120 CTF-150 CTF-200 CTF-250
Rated Current, AC51 -
AC55b Resistive Load
25A
40A
50A
60A
75A
90A
120A
(@ 40˚C contin. service)
Rated current AC56A
permitted trigger
modes: ZC, BF/DOT
20A
32A
40A
50A
60A
75A
100A
with DT (Delay Trigger),
PA with softstart
(@ Tamb = 40 °C)
Maximum Surge Current
400A
520A
520A
1150A
1150A
1500A
1500A
(t = 10 ms) A
Maximum I
2
t for fusing
450
1,800
1,800
6,600
6,600
11,200
11,200
(blowout) A
2
s
Critical dV/dt Off-state
1,000V/µs
(minimum)
Nom. Impulse Voltage
4KV
Nominal SCCR
5KA
CTF 150 A, 200 A, 250 A
4.3 (108.3)
3.3 (84)
5 (127)
1.7 (42)
1.2 (30)
3.9
(100)
11.3
(287.4)
1.3
Fan
(32)
11.9
(302)
W
L
Depth: 6.7 (170.4)
Weight: 5.7 lb. (2,600 g)
FUNCTION
Detection of shorted load circuit,
Diagnostics
absence of line voltage, HB alarm (partial break of load)
OPTIONS
- Timed Soft-Start firing ramp, with or without peak current control
- Soft-Start firing ramp (specific for infrared lamps)
Options
- Timed shut-off ramp
- Limitation of RMS current in load
- 0-90° Delay-Triggering for firing inductive loads in ZC and BF/DOT modes.
- SCR in short circuit (presence of current with OFF control)
- Absence of SCR current when under load.
- Overtemperature alarm
Current read
Diagnostic
• HB alarm: interrupted or partially interrupted load
• Automatic calibration of HB alarm setpoint starting from current value in load
• Alarm for load in short circuit or overcurrent
Voltage read
• No line voltage
GENERAL DATA
690 Vac
CTF 25-120 A: 24 Vac 50-60 Hz / Vdc ± 25%, max 3 VA
Power Supply
90 - 760V ac
CTF 150-250 A: 24 Vac 50-60 Hz / Vdc ± 25%, max 11 VA
1600 Vp
Power supply for external fan
24 Vdc ± 10%, max 200mA
(only for CTF120A model)
5 leds: RUN: run state of CPU
STATUS: operating state
Signals
ALARM: state of alarm output
150A
200A
250A
DIGITAL INPUT: state of digital inputs
ON / OVER-TEMP.: state of SCR power / Alarm for overheating
Single phase load
Independent single-phase load in open delta
Load Type and Connection
125A
160A
200A
3-phase load
3-phase load (star without neutral or closed triangle) with 2-leg control
Protection
IP20
0 to 50˚C (32 to 122˚F) (Per EN 60947-4-3 § 7.1.1: Average Temperature over 24
5000A
8000A
8000A
Ambient Temperature
hour period shal not exceed 35˚C (95˚F)
125,000 320,000 320,000
Storage Temperature
-20˚C to 70˚C (-4˚F to 158˚F)
Relative Humidity
20...85% RH non-condensing
Ambient Conditions for use
Indoor use, altitude up to 2000m
Installation
DIN Rail EN50022 or panel with screws
Installation category II, pollution level 2, double isolation (only for model >120A):
- Max. temperature of air surrounding device 40°C; for temperature >40°C refer
Installation Requirements
at derating curves
- Device type: "UL Open Type"
4. DERATING CURVES
Minimum Spacing Requirements
6. FUSES & FUSE HOLDERS
CTF Model
480 & 600 Vac
Fuse
Power
unless otherwise
Rating,
Dissi-
specified
Amps
I
2
t
pation Fuse Size
CTF-25
25A
390 A²s
CTF-40
50A
1,600 A²s
9.5W
CTF-50
50A
1,600 A²s
9.5W
CTF-60
63A
3,080 A²s
CTF-75
80A
6,600 A²s
CTF-90
125A
6,950 A²s
CTF-120
125A
6,950 A²s
CTF-150
200A
31,500 A²s
CTF-200/250
450A
196,000 A²s
CTF-200/250 @690V
400A
150,000 A²s
Fuse
Power
Rating,
Dissi-
CTF Model
Amps
I
2
t
pation Fuse Size
All Models
1A
N/A
CTF-025 & CTF-040
45
70
40
40
65
40
;7*
60
35
35
55
97*
30
30
50
25
25
45
25
22.5
40
20
20
35
30
15
0
0
40
45
50
Enclosure / Ambient Temperature ˚C
Enclosure / Ambient Temperature ˚C
CTF-75, CTF-90, CTF-120
125
275
120
120
120
250
115
250
107.5
110
105
225
100
95
200
95
90
90
200
90
85
175
80
80
75
75
150
75
70
150
67.5
70
65
60
125
60
55
100
0
40
45
50
0
Enclosure / Ambient Temperature ˚C
Enclosure / Ambient Temperature ˚C
I
2
t Extra Rapid Fuses
Manufacturer's
Model Code
Part No.
Part No.
6W
10x38
FWC25A10F
0024-07815
0024-12124
22x58
FWP50A22F
0024-07816
0024-12199
22x58
FWP50A22F
0024-07816
0024-12199
11W
22x58
FWP63A22F
0024-07817
0024-12199
14W
22x58
FWP80A22F
0024-07818
0024-12199
25W
100x51x30
170M2665
0024-07819
0024-12029
25W
100x51x30
170M2665
0024-07819
0024-12029
19W
FUS-200S DN000UB69V200
0024-07820
Fuse is mounted internal to the controller
17W
FUS-450S DN00UB60V450L
0024-07821
Fuse is mounted internal to the controller
20W
FUS-400S DN00UB69V400L
0024-07822
Fuse is mounted internal to the controller
Instrument Fuse
Manufacturer's
Model Code
Part No.
Part No.
N/A
10x38
KTK-1
0024-01113
0024-12124
CTF-050 & CTF-060
;7*
99*
97*
97*
:9*
:7*
40
45
50
CTF-150, CTF-200, CTF-250
250
225
200
200
180
160
150
135
120
40
45
50
Fuse Holder
Fuse Holder
Fuse Holder
Rating (UL)
Rating (IEC)
30A@600V
32A@690V
100A@600V
125A@690V
100A@600V
125A@690V
100A@600V
125A@690V
100A@600V
125A@690V
400A@600V *not CE-marked
400A@600V *not CE-marked
Fuse Holder
Fuse Holder
Fuse Holder
Rating (UL)
Rating (IEC)
30A@600V
32A@690V
PK536
0037-75558
August 2015