Installation of the treated water tap (Fig. 6)
• Drill a 12 mm hole in the sink (benchtop).
• Place the rubber gasket (2), the decorative plate
(3), the rubber gasket (4) on the threaded shank
of the tap (1) and insert the tap into the sink hole.
• Put the plastic (5) and the metal (6) lock washers
on the threaded shank from the bottom of the
benchtop and screw the fixing nut (7) until tight
(you can use a 14 mm pipe wrench).
• Insert the metal sleeve (8) into the blue tube (10),
and the tube into the threaded shank of the tap
(1) and tighten the clamping nut (9) until tight.
• Check that the tube (10) is tight. The tube should
not be pulled out with a force of 8–10 kgf.
Attention! It is recommended to use the stand-
ard RO-202S tap for treated water. Using other
taps may result in humming and other unusual
sounds.
Installation of the drain clamp* (Fig. 7)
• It is recommended to install the clamp on the
sink drain upstream the S-trap (the drain clamp
fits most drain pipes about 40 mm in diameter).
• Attach the part of the clamp with the fitting to
the pipe and find the optimal position of the
clamp and a hole for the tube.
• Drill a 7 mm hole in the pipe wall in the intended
place.
• Remove the cut round part from the gasket (1).
• Remove the protective film (2) from the gasket (1).
Attach the gasket (1) on the inside of the clamp
so that the hole in the gasket aligns with the
hole in the clamp fitting.
• Install the clamp on the pipe, aligning the hole
in the fitting with the drilled hole in the pipe,
and then tighten the bolts (3). The bolts should
be tightened evenly so that the two parts of
the clamp are parallel.
• Put the plastic nut on the JG drain tube so that
the tube extends from the other side of the nut
by at least 20 mm (Fig. 7b).
• Insert the tube into the drain clamp and screw
the nut onto the fitting.
Note. Push the JG tube deeper into the pipe if
you are disturbed by the sound of water coming
from the drain clamp.