PRODUCT SPECIFIC SAFEGUARDS
• Do not look at an unshielded UV-C globe. Ultra Violet light is harmful to your eyes and may cause blindness. Do not
operate UV Globe out of the housing.
• As the UV Clarifier Globe is made of quartz glass, please avoid sudden jolts, as this will break the quartz.
• In cold temperatures where frost or freezing may occur, please cease to use the unit. Remove from the environment.
Frozen water will crack the Quartz glass sleeve.
INSTALLATION
Once a fountain nozzle has been selected, assemble the fountain kit as per the attached diagram. Screw the T-piece
onto the pump outlet and adjust the telescopic riser to the desired height and align vertically. On the Dual-control flow
adjuster, on the T-piece, you can vary the flow between the fountain head and the waterfall outlet. Close the second
outlet of the T-piece if this is not required for an optional waterfall.
Position the device in the pond horizontally, on a solid base, free from sludge, in such a way that it is fully covered with
water and the fountain kit protruding out of the water.
Insert the two pin Low Voltage plug into the Low Voltage side of the transformer and secure with the locking nut. Insert
the mains power supply plug into the power outlet.
Note: Use the power supply switch for turning the unit on and off.
CLEANING INSTRUCTIONS
Begin by ensuring that the mains power supply is disconnected before attempting any maintenance or adjustment of
the unit. Remove the unit from the water. The filters and sponges in this unit will clog over time. Please clean regularly
(at least once a month) to ensure strong water flow. Failure to maintain the unit will result in a burnt out motor and
other damage.
• Unscrew the safety screw towards the end of the unit. This is found underneath the holder, at the one end.
• Take off the fountain set first, and then open the two clips on the side of the filter cover.
• Take out the filter sponge and filter media boxes and clean. It is recommended that this is done in a bucket of pond
water to ensure the good bacteria are not killed by the Chlorine in tap water. Check for wear and tear of the sponges.
Replace if necessary.
• Maintain the filter sponge regularly according to how quickly the sponge gets clogged up. When the flow starts to get
reduced, check and clean if necessary.
• You can help boost the biological function of your filter with a bacterial additive, available from your local stockist.
• The UV lamp should be replaced regularly at the end of its design life. Usually this around 11 months of use. To
take out the UV clarifier globe, open the safety catch on the side and turn the UV Clarifier casing in anti-clockwise
direction to the stop position. Then slide out the 5W/9W LV quartz glass globe. Now you can change your UV lamp.
• Dirt on the Quartz sleeve will influence the efficiencies of the equipment. Please remove and clean regularly.
• To clean the quartz glass sleeve, take the quartz sleeve out by unfastening the locking nut (No. 4 Fig. 3). Then you can
take out the quartz glass sleeve and clean.
• To maintain the impeller of the pump, turn the Impellor cover in an anti-clockwise direction to the stop position, and
then you can separate the impeller cover and pump body. Take out the impeller, clean it with clean water and suitable
brush. Inspect for signs for ware. Replace if necessary.
• Once the cleaning and inspection process is completed, reassemble in the revers manner. The pump suction elbow is
pushed firmly onto the Impellor cover inlet of the pump. Pay attention to the UV clarifier casing when inserting it back
together. The inspection hole needs to be positioned towards the top, you can separate the impeller cover and pump
body.
• Take out the Impellor, clean it with clean water and suitable brush. Inspect for signs for ware. Replace if necessary.