AquaPRO PRO1502403 Посібник користувача - Сторінка 3

Переглянути онлайн або завантажити pdf Посібник користувача для Повітродувка AquaPRO PRO1502403. AquaPRO PRO1502403 4 сторінки. Spa blower
Також для AquaPRO PRO1502403: Посібник користувача (8 сторінок)

Operating Instructions and Parts Manual
Troubleshooting Chart -
All repairs must be completed by licensed or certified professionals.
Symptom
Possible Cause(s)
Corrective Action(s)
Blower will not
1.
Power Off
1.
start
2.
Internal blower
2.
overload trips
3.
Brushes worn out
3.
4.
Nuisance trips
4.
Blower hums but
1.
Rotor locked
1.
will not run
2.
Brushes worn out
2.
3.
Wrong voltage
3.
Blower runs but
1.
Low voltage
1.
delivers little air
2.
Blower too small for
2.
application
3.
Check valve installed
3.
incorrectly
Internal blower
1.
Blocked or restricted
1.
overload trips
air line
2.
Check valve installed
2.
incorrectly
Blower runs too
1.
Incorrect line voltage
1.
slow
2.
Incorrect wire size
2.
877.278.2797
Safety Alert
Check electrical connections and fuse
Disconnect power
box / control panel
BEFORE taking any
Disconnect power then check for
corrective action(s)
restrictions or blockage in air discharge
line
Replace motor
It is possible that if the blower is started
and stopped repeatedly in a short time
period, the thermal overload could
interrupt the circuit. Allow the unit to
cool and disconnect power. Restart after
5 - 15 minutes (depending on warmth
of ambient conditions).
Disconnect power then check for debris
Disconnect power
or foreign object lodged in blower
BEFORE taking any
motor
corrective action(s)
Replace motor
Verify voltage is correct for blower
Check electrical connections
Disconnect power
Verify voltage is correct for blower
BEFORE taking any
Install additional blowers, or reduce
corrective action(s)
piping restrictions
Re-orient check valve
Check for debris or foreign object
Disconnect power
lodged in discharge line
BEFORE taking any
Re-orient check valve
corrective action(s)
Check blower voltage requirements,
Disconnect power
make certain line voltage is correct
BEFORE taking any
Verify correct wire gage is being used
corrective action(s)
www.aquaprosystems.com
4
Operating Instructions and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
The Air Blower is designed for outdoor
hazardous situation which, if not
spa applications. It is designed for low
avoided, COULD result in death or
noise and a high air flow rate. The unit
serious injury.
is UL listed and the motor is protected
with a resetting thermal overload
hazardous situation which, if not
device. The blower is designed for
avoided, MAY result in minor or
permanent electrical connections.
moderate injury.
The box contains the following:
Blower
information, that if not followed, may
Mounting Bracket
cause damage to equipment.
UL Approved Check Valve
Conduit Cover Plate, Gasket, and
General Safety
Screws
Information
Instruction Manual
Unpacking/Unit Inspection
CALIFORNIA PROPOSITION 65
After unpacking the blower, carefully
inspect for any damage that may have
contain chemicals, including lead,
occurred during transit. Check for
known to the State of California to
loose, missing or damaged parts.
cause cancer and birth defects or other
DAMAGE TO THE UNIT DURING
reproductive harm. Wash hands after
TRANSPORTATION IS NOT THE
handling.
RESPONSIBILITY OF THE
GENERAL
MANUFACTURER.
Important Safety
allow children to use this product
Instructions
unless they are closely supervised at all
times.
When installing and using this
electrical equipment, basic safety
precautions should always be
(305 mm) above the maximum water
followed.
level to prevent water from contacting
electrical equipment. Install in
READ AND FOLLOW ALL
accordance with the installation
INSTRUCTIONS.
instructions.
Safety Guidelines
This manual contains information that
Install blower at least two feet above
is very important to know and
the ground in an area free of debris,
understand. This information is
chemicals, or sprinklers.
provided for SAFETY and to PREVENT
ELECTRICAL
EQUIPMENT PROBLEMS. To help
recognize this information, observe
the following symbols:
Disconnect power before
Danger indicates
attempting to install, service,
an imminently
relocate or perform any
hazardous situation which, if not
maintenance. Tag and disconnect
avoided, will result in death or serious
power and lock the fuse box / control
injury.
panel to prevent unexpected
application of power.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
www.aquaprosystems.com
PRO1002403, PRO1502403, PRO2002403,
PRO100120, PRO150120, and PRO200120
Risk of
Warning indicates
Electric
a potentially
Shock. Install blower at least
5 feet (1.5 m) from pool / spa
water using nonmetallic
plumbing.
Caution indicates
To reduce
a potentially
the risk
of electrical shock, connect
the green colored wire inside
the electrical box to the
Notice indicates
grounding terminal of your electrical
important
service or supply with a continuous
green insulated solid copper conductor
minimum No. 8 AWG (8.4 mm2) solid
copper conductor between this unit
and any metal equipment, metal
enclosures of electrical equipment,
metal water pipe, or conduit within 5
feet (1.5 m) of the unit.
SAVE THESE INSTRUCTIONS.
This product or its
power cord may
Installation
Guidelines
Failure to observe
installation
guidelines, could result in death or
To reduce the risk
serious injury.
of injury, do not
See Figure 1 for recommended
installation diagram.
1. Install at least 5 feet (1.5 m) from
Install blower no
pool / spa water using nonmetallic
less than 1 foot
plumbing. Install blower no less
than 1 foot (305 mm) above the
maximum water level to prevent
water from contacting electrical
equipment. Install in accordance
Blower is designed
with the installation instructions.
for outdoor use.
2. The check valve supplied with the
unit must be installed in a vertical
orientation above the water level
in an easily accessible location for
serviceability. Take care to orient
the check valve with the arrow
pointing in the direction of the air
flow inside the pipe.
3. Use a separate dedicated 2-inch
rigid PVC supply line from the
blower to the spa.
877.278.2797
1