5.1) Standards
• Heating System – during installation and operation of the boiler it is very
important to keep safe distance from the inflammable materials. The boiler
is allowed to work only in open type heating systems!
• Electrical installation – the regulator's power supply is 230V/50Hz
• Chimney – It must be done with respect to current norms and regulations.
Due boiler gasses temperature 90-100 C it is obligatory to put the INOX
or other material tubes into the chimney. Required chimney draught is
0,1 – 0,2 mbar. Installation according to ADJ does entail some testing of
the chimney, which may be carried out by a sweep
• Important sources of guidance installers: 98/37/EEG; 89/336/EEG;
73/23/EEG; EN 55014-1, 1993 /A1, 1997; EN 55014-1; EN 55014-2 C1
1998; EN 61000-3-2; EN 61000-4-2, -3-4-5-6-11, Level2; EN 50165; EN
50165 C1; EN 60335-1; EN 303-5; EN 12809; EN 13394
5.2) Combustion ducts, ventilation:
At
connecting
recommendations:
To provide the correct work of device the chimney draught should figure
out about 15 Pa.
The flue should be performed from heat-resistant steel and leaded
straight as possible and with the smallest number of deflecting.
Connecting flue with chimney should be made at an angle of 45º.
The assembly of simple section after exit from flue connection courts
about length min. 30 cm directly.
The connections of flue should be tight.
Fireplace should be connected to individual flue.
External chimneys should be insulated.
Room in which fireplace will be installed should be equipped in
ventilations.
The minimum intersection of chimney is 400 cm2 and height this 6-8 m.
Air to fireplace should be brought by channel about intersection
=100mm