Panasonic CT-24SX11CE Посібник з експлуатації - Сторінка 4
Переглянути онлайн або завантажити pdf Посібник з експлуатації для ТЕЛЕБАЧЕННЯ Panasonic CT-24SX11CE. Panasonic CT-24SX11CE 36 сторінок.
IMPORTANT: To protect against possible damage to
the solid state devices due to arcing or static
discharge, make certain that all ground wires and CTR
DAG wire are securely connected.
CAUTION: The power supply circuit is above earth
ground and the chassis cannot be polarized. Use an
isolation transformer when servicing the Receiver to
avoid damage to the test equipment or to the chassis.
Connect the test equipment to the proper groun ( ) or
(
) when servicing, or incorrect voltages will be
measured.
BOARD
A-BOARD
C-BOARD
P-BOARD
Example: To order the A-Board, the replacement board is
Service Notes (Continued)
Board Table Description
PART NUMBER
TNP2AH025CA
TNP2AA068AF
TNP2AH025CA
* Note: When ordering a replacement board assembly,
append an "S" to the board number.
TNP2AH025CAS.
WARNING: This Receiver has been designed to meet
or exceed applicable safety and X-ray radiation
protection as specified by government agencies and
independent testing laboratories.
To maintain original product safety design standards
relative to X-ray radiation and shock and fire hazard,
parts indicated with the symbol
must be replaced with identical parts. Order parts from
the manufacturer's parts center using the parts
numbers shown in this service manual, or provide the
chassis number and the part reference number.
For optimum performance and reliability, all other parts
should
be
replaced
identical specification.
BOARD DESCRIPTION
Main board
CRT panel
Power Supply Board
- 4 -
on the schematic
with
components
of