HP 1810-8G v2 Технічний паспорт - Сторінка 4

Переглянути онлайн або завантажити pdf Технічний паспорт для Перемикач HP 1810-8G v2. HP 1810-8G v2 11 сторінок. Smart-managed, fixed-configuration gigabit and fast ethernet layer 2 switches
Також для HP 1810-8G v2: Технічні характеристики (32 сторінок), Quickspecs (32 сторінок)

HP 1810-8G v2 Технічний паспорт
HP 1810 Switch Series

Specifications

Ports
Physical characteristics
Weight
Memory and processor
Mounting
Performance
100 Mb Latency
1000 Mb Latency
Throughput
Switching capacity
MAC address table size
Environment
Operating temperature
Operating relative humidity
Nonoperating/Storage temperature
Nonoperating/Storage relative humidity 15% to 95% @ 140°F (60°C)
Altitude
Acoustic
Electrical characteristics
Maximum heat dissipation
Voltage
Current
Maximum power rating
Frequency
Notes
Safety
Emissions
Immunity
ESD
Radiated
EFT/Burst
Surge
Conducted
Power frequency magnetic field
Voltage dips and interruptions
Harmonics
Flicker
4
HP 1810-8G v2 Switch (J9802A)
8 RJ-45 autosensing 10/100/1000 ports (IEEE 802.3
Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE
802.3ab Type 1000BASE-T); Duplex:
10BASE-T/100BASE-TX: half or full; 1000BASE-T: full
only
Supports a maximum of 8 autosensing 10/100/1000
ports
7.93(w) x 4.65(d) x 1.73(h) in (20.14 x 11.81 x 4.4 cm)
(1U height)
0.84 lb (.38 kg)
128 MB RAM, 8 MB flash; packet buffer size: 512 KB
wall, desktop and under table mounting
< 3.3 µs (64-byte packets)
< 2.3 µs (64-byte packets)
up to 11.9 million pps
16 Gbps
8000 entries
0°F to 40°F (-17.8°C to 4.4°C)
15% to 95% @ 104°F (40°C)
-40°F to 158°F (-40°C to 70°C)
up to 10,000 ft (3 km)
Power: 0 dB no fan
100-240 VAC
.5 A
7.2 W
50/60 Hz
Maximum power rating and maximum heat dissipation
are the worst-case theoretical maximum numbers
provided for planning the infrastructure with fully
loaded PoE (if equipped), 100% traffic, all ports plugged
in, and all modules populated.
UL 60950-1; IEC 60950; EN 60950
EN 55022 Class A; CISPR 22 Class A; VCCI V-3; FCC (CFR
47, Part 15) Subpart B Class A; VCCI V-4
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
EN 61000-3-2
EN 61000-3-3
HP 1810-24G v2 Switch (J9803A)
24 RJ-45 autosensing 10/100/1000 ports (IEEE 802.3
Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE
802.3ab Type 1000BASE-T); Duplex:
10BASE-T/100BASE-TX: half or full; 1000BASE-T: full
only
2 SFP autosensing 100/1000 ports (IEEE 802.3u Type
100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex:
100BASE-TX: half or full; 1000BASE-T: full only
Supports a maximum of 24 autosensing 10/100/1000
ports plus 2 SFP ports
12.99(w) x 6.81(d) x 1.73(h) in (32.99 x 17.3 x 4.4 cm)
(1U height)
2.54 lb (1.15 kg)
128 MB RAM, 8 MB flash; packet buffer size: 512 KB
Mounts in an EIA-standard 19 in. telco rack (hardware
included), horizontal surface, wall and under table
mounting
< 3.3 µs (64-byte packets)
< 2.2 µs (64-byte packets)
up to 38.7 million pps
52 Gbps
8000 entries
0°F to 40°F (-17.8°C to 4.4°C)
15% to 95% @ 104°F (40°C)
-40°F to 158°F (-40°C to 70°C)
15% to 95% @ 140°F (60°C)
up to 10,000 ft (3 km)
Power: 0 dB no fan
100-127/200-240 VAC
.4/.3 A
22 W
50/60 Hz
Maximum power rating and maximum heat dissipation
are the worst-case theoretical maximum numbers
provided for planning the infrastructure with fully
loaded PoE (if equipped), 100% traffic, all ports plugged
in, and all modules populated.
UL 60950-1; IEC 60950; EN 60950
EN 55022 Class A; CISPR 22 Class A; VCCI V-3; FCC (CFR
47, Part 15) Subpart B Class A; VCCI V-4
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
EN 61000-3-2
EN 61000-3-3
HP 1810-48G Switch (J9660A)
48 RJ-45 autosensing 10/100/1000 ports (IEEE 802.3
Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE
802.3ab Type 1000BASE-T); Duplex:
10BASE-T/100BASE-TX: half or full; 1000BASE-T: full
only
4 SFP autosensing 100/1000 ports (IEEE 802.3u Type
100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex:
100BASE-TX: half or full; 1000BASE-T: full only
Supports a maximum of 48 autosensing 10/100/1000
ports plus 4 SFP ports
17.4(w) x 9.75(d) x 1.75(h) in (44.2 x 24.77 x 4.45 cm)
(1U height)
6.31 lb (2.86 kg)
8 MB flash, 64 MB SDRAM; packet buffer size: 1.5 MB
Mounts in an EIA-standard 19 in. telco rack (hardware
included); wall, desktop, tabletop, and under-table
mounting
< 8.4 µs (64-byte packets)
< 3.2 µs (64-byte packets)
up to 77.4 million pps (64-byte packets)
104 Gbps
16000 entries
32°F to 113°F (0°C to 45°C)
15% to 95% @ 104°F (40°C), noncondensing
-40°F to 158°F (-40°C to 70°C)
15% to 90% @ 149°F (65°C), noncondensing
up to 10,000 ft (3 km)
Power: 22 dB single fan
204 BTU/hr (215.22 kJ/hr)
100-127/200-240 VAC
0.9/0.5 A
60 W
50/60 Hz
Maximum power rating and maximum heat dissipation
are the worst-case theoretical maximum numbers
provided for planning the infrastructure with fully
loaded PoE (if equipped), 100% traffic, all ports plugged
in, and all modules populated.
CSA 22.2 No. 60950; EN 60950/IEC 60950; UL 60950
EN 55022 Class A; CISPR 22 Class A; VCCI V-3; FCC (CFR
47, Part 15) Subpart B Class A; VCCI V-4
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
EN 61000-3-2
EN 61000-3-3