Fabric OS 6.1.2b fixes
Table 16
lists defects closed in the Fabric OS 6.1.2b firmware release.
Table 16 Fabric OS 6.1.2ab closed defects
Closed defect summary
CALD allocated shared memory may not be released, causing the
switch to run out of shared memory, leading to high CPU load and
inability to run CLI commands.
SNMPd panic/restart due to segmentation fault caused by out of
memory condition. Caused by FSPF timeout with neighbor switch during
out of memory recovery.
A switch panic occurs due to CALD memory leak leading to out of
memory condition while running management applications.
Class 2 ACK is not forwarded from F_Port to N_Port in Access Gateway
mode, causing the Name Server to abort the exchange.
HP StorageWorks 8/40 switch may get an error message, after a
power cycle, that Fan/PS is not supplying power and fan speeds not
available.
Solution
Workaround prior to upgrade: Run
HA failover to workaround this issue.
Fixed in Fabric OS 6.1.2b.
Fixed in Fabric OS 6.1.2b.
Fixed in Fabric OS 6.1.2b.
Fixed in Fabric OS 6.1.2b.
Workaround prior to upgrade: When
the failure is seen at switch boot up
time, it can be safely ignored; it
results from spurious sensor reading
below minimum.
Fixed in Fabric OS 6.1.2b.
HP StorageWorks Fabric OS 6.1.2b release notes
31