HP surestore fc 1Gb entry switch 8B Посібник - Сторінка 35
Переглянути онлайн або завантажити pdf Посібник для Перемикач HP surestore fc 1Gb entry switch 8B. HP surestore fc 1Gb entry switch 8B 50 сторінок. Fabric os procedures guide (version 3.0)
Displaying the Error Log of a Switch
There are two ways to display the error log of a switch:
•
Display the error log one page at a time
•
Display the error log all at once
To display the switch error log one page at a time:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
ErrShow
To display the switch error log all at once:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
ErrDump
Displaying the Switch Status
The switch status can be either Healthy/OK, Marginal/Warning, or Down. The overall status of a
switch is determined by the status of several individual components within the switch. For more
information on how the overall switch status is determined, refer to the switchStatusPolicySet
command in the Fabric OS Reference Manual.
To display the overall status of a switch:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
switchStatusShow
The status of the switch should be Healthy/OK. If the status is Marginal/Warning or Down, the
components contributing to this status are displayed.
Displaying Information About a Switch
To display switch information:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
switchShow
This command displays the following information for a switch:
•
•
•
Fabric OS Procedures Guide
switchName - the switch's name
switchType - The switch's model and firmware version numbers.
switchState - The switch's state: Online, Offline, Testing, or Faulty.
Displaying Error Logs and Status
4
4-3