HP surestore fc 2Gb entry switch 8B Посібник - Сторінка 34

Переглянути онлайн або завантажити pdf Посібник для Перемикач HP surestore fc 2Gb entry switch 8B. HP surestore fc 2Gb entry switch 8B 50 сторінок. Fabric os procedures guide (version 3.0)

4
Displaying Error Logs and Status
where portnumber is the number of the port you want to view. A table of hardware statistics
for the port is displayed.
Note:

Displaying a Summary of Port Errors

This command displays a summary of port errors for all the ports in a single switch.
To display a summary of port errors for a switch:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
portErrshow
The display contains one output line per port. The following table explains the types of errors
counted:
Table 4-1
Error Type
frames tx
frames rx
enc in
crc err
too shrt
too long
bad eof
enc out
disc c3
link fail
loss sync
loss sig
frjt
fbsy
Note:
4-2
For more information on the portStatsShow command, refer to the Fabric OS Reference
Manual.
Error Summary Description
Description
Frames transmitted.
Frames received.
Encoding errors inside frames.
Frames with CRC errors.
Frames shorter than minimum.
Frames longer than maximum.
Frames with bad end-of-frame delimiters.
Encoding error outside of frames.
Class 3 frames discarded.
Link failures (LF1 or LF2 states).
Loss of synchronization.
Loss of signal.
Frames rejected with F_RJT.
Frames busied with F_BSY.
For more information on the portErrShow command refer to the Fabric OS Reference
Manual.
Fabric OS Procedures Guide