Panasonic PT-L6510E Інструкція з експлуатації Посібник з експлуатації - Сторінка 40

Переглянути онлайн або завантажити pdf Інструкція з експлуатації Посібник з експлуатації для Проектор Panasonic PT-L6510E. Panasonic PT-L6510E 50 сторінок. 3600 ansi lumens sxga lcd projector 4200 ansi lumens xga lcd projector
Також для Panasonic PT-L6510E: Брошура та технічні характеристики (6 сторінок)

Panasonic PT-L6510E Інструкція з експлуатації Посібник з експлуатації

Indication of lamp monitor

This projector is equipped with 3 indicators to show when a lamp needs replacement or there is an abnormal
internal temperature. These lamps flash or light up to indicate a problem.
Turn the power off and follow the steps below.
Indicator
Temperature
monitor
TEMP
Lamp monitor
LAMP1
LAMP2
Caution
• To solve any problems that the TEMP and LAMP monitor show, first turn the power off by following the steps
on page 23.
• If the main power turns off after the TEMP monitor flashes, the projector has malfunctioned. Please consult
your dealer.
40
Display
Condition
The inside is at an
Red lamp
abnormally high
flasing
temperature, or there
(lamp unit lit)
are sudden
(PT-L6510E)
temperature changes.
The ambient
Red lamp lit
temperature or internal
(lamp unit lit)
temperature is high.
The lamp unit
Red lamp
automatically shuts off
flashing
(switches to standby
(lamp unit
state) due to abnormally
not lit)
high ambient
temperature or internal
temperature.
The lamp unit has
automatically turned
Red lamp lit
off (standby mode)
(Lamp unit
because of a high
not lit)
temperature or
(PT-L6600E)
sudden rise in
internal temperature.
It is time to replace
Red lamp lit
the lamp unit.
Detected the Lamp
Red lamp
curcuit abnormal
flashing
condition.
STAND BY (R) LAMP1
LAMP2
TEMP
ON (G)
(Rear view of projector)
Check
• Is something
blocking the vent?
• Has the projector
been operating in a
hot location?
• Is the air filter
clogged?
Is replace lamp
displayed on the
screen when the
power is turned on?
Are you turning the
power back on
immediately after it has
been turned off?
There is a
malfunction in the
lamp circuit
Lamp 1 monitor (LAMP 1)
Lamp 2 monitor (LAMP 2)
Temperature monitor (TEMP) indicator
Measures
• Remove the object blocking the
vent.
• Use the projector only in an
environment having a temperature of
0 C to 40 C and humidity of 20% to
80% (with no condensation).
• Turn the power off by following the
steps on page 23 and clean the air
filter. (See page 41)
Lights when lamp runtime exceeds
1800 hours. Have your dealer
replace the lamp unit.
Wait until the light source lamp cools
off before turning the power back on.
Turn the power off by following the
steps on page 23 and consult your
dealer.