UV Lamp and Quartz Sleeve Replacement
For units with UV lights it is recommended that a new lamp
be installed after 12 months of use. While the light might
still turn on, the effectiveness of the UV light diminishes
over time. Quartz sleeves are typically long lasting and only
require replacement if they break or develop a leak due to
the age of the seals.
UV Lamp Replacement
1. Unplug the UV unit and the pump.
2. Remove thumbscrew from clear lid on top of unit.
Remove the clear lid. TIP: Use it to hold the various
screws during the process.
3. Remove the two screws and the plastic cord retainer
clip.
4. Remove the three screws that hold the UV lamp
assembly in the unit. Take care not to lose any of the
screws during this process.
5. Remove the UV assembly from the unit.
6. Remove the old UV lamp.
7. Carefully remove the black stabilizing protector on the
end of the old lamp.
8. Do not touch the new lamp with your fingers. The
oil from your skin can cause pre-mature failure of
the lamp.
9. Hold the new UV lamp with a glove or clean cloth and
plug into the UV housing. Transfer the black stabilizing
protector unit to the new lamp.
10. Carefully slide the assembly with the new lamp back
into place and secure it with screws.
11. Reattach the cord retainer clip with the two screws.
12. Replace the clear top cover and secure with
thumbscrew.
13. Return the unit back to service.
6
Step 2
Step 3
Step 4