Chapter 2 - System Requirements
» Wire Types
All wiring should be #18AWG except for the selective "L" wires which can be #22AWG. Either stranded or solid core wire
is acceptable. No shielded or twisted pair type wire is required.
» Installation Procedures
All components must be installed in a cool, clean and dry location. All connections must be clean and secure to insure reli-
able operation. Some installations or local codes may require installation of annunciator controllers in a protective junction
box with its transformer and the transformer's primary 120VAC connections.
» System Operation
The AlphaEcall™ 100 Series system is designed as a single priority level, emergency call system. With the AC219 Annun-
ciator Controller, mechanically latching devices of various sorts are used to send an alert to a master station or multiple
master stations connected in parallel. The AlphaEcall™ 100 Series system can support corridor lights, zone lights, and
can trigger floor bells, strobes, and many other audible and/or visual annunciators. When any call is active, the tone light
will light and the tone will sound. To silence the tone, press the Tone Off button; the Tone Off light and the tone will shut off
and remain off until ALL calls are reset. All call resets must be done at the originating station(s).
» IMPORTANT NOTES
•
To ensure system reliability and longevity, please check that all hardware is installed and configured as per manu-
facturer's recommendations and manufacturer's distance limitations and cabling requirements are observed.
•
When planning your installation, consider distance limitations, and potential electromagnetic interference (EMI)
sources.
•
As this is considered a Life Safety system, it is recommended that a quality Battery back up/surge protector/ power
filter be used for all devices and components connected to 110VAC power.
•
Systems being used for emergency call, door monitoring, or any other critical application should have their devices
tested regularly for proper operation.