dicodes Dani Extreme V2+ Посібник - Сторінка 10
Переглянути онлайн або завантажити pdf Посібник для Регулятор температури dicodes Dani Extreme V2+. dicodes Dani Extreme V2+ 12 сторінок.
Також для dicodes Dani Extreme V2+: Посібник (12 сторінок)
06 Extended Functions Menu
06 Extended Functions Menu
Additional Explanation to several menu items, page 2
Weitere Erläuterungen zu einzelnen Punkten im Extended Functions Menü Seite 2
The display mode switches on and off the dynamic display of several parameters during
the vape.
With display mode =1 and temperature controlled mode, these parameters are the
temperature, coil resistance, temperature regulating power and battery voltage.
For the modes standard, boost and heater protection the selected power (static, no
change), the coil resistance and the battery voltage are displayed.
When Bypass mode is selected, the coil resistance and battery voltage dependent,
calculated power is displayed, as there is no fixed power setting in bypass mode.
When display mode =0 is selected, the values of the mentioned parameters at the end
of the vape are displayed for about 4 seconds. In this case the values will not vary of
course.
The Dani Extreme V2 can be used in 5 different modes. But in order to keep the menu
as short and simple as possible, 3 of the 5 modes are only available, if the Expert-Mode
is set to 1. The name is Expert-Mode, because the use of the additional operation modes
requires additional knowledge about their functionality.
The additional modes available with Expert Mode set to 1 are "Power Boost",
"Heater Protection" and "Bypass".
Here again the modes in an overview:
- Standard:
- Temperature The power applied to the coil is calculated by a temperature controller
Control:
- Power Boost: The coil is quickly heated up initially. Moreover an repetitive boost can be
- Heater Protection: The power to the coil is repetively interrupted to enable a liquid
- Bypass:
Vaping with a constant power setting. The selected power is applied to the
coil, unless the coil's resistance affords a different power setting.
which keeps the coil's temperature constant. Important to note: Set the
right temperature coefficient and perform a calibration at room temp.
selected. Note to not to set the power limit to a value too low and use
lower normal power setting.
flow und to limit the temperature.
The mod behaves like a mechanical mod, i.e. the battery voltage is directly
applied to the coil. This with the restriction, that the maximum current
is limited 15A. Note that the vape now depends on the charging level
of the battery, and the coil should not be very low in resistance as then
15A is reached soon.