Alpha Group Out Back Power MATE Series Огляд - Сторінка 10
Переглянути онлайн або завантажити pdf Огляд для Блок управління Alpha Group Out Back Power MATE Series. Alpha Group Out Back Power MATE Series 14 сторінок. System display and controller
Changing more detailed operating parameters
requires access to the Advanced Setup Menu.
Accessing the Advanced Menu:
MAIN--------------------
3:02:14P
SUM STATUS SETUP ADV
ADV/SETTINGS/WARNING
changes made could
adversely affect
system performance
ADV/PASSWORD------------
Enter the password
132
ENTER INC
DEC
EXIT
A
1. Press the <INC> soft key
A
until "141" is displayed on
the LCD.
2. Press the <ENTER> soft key
B
to accept the password and
move forward to the Device
Selection Menu.
ADV/PASSOWRD------------
Enter the password
141
ENTER INC
DEC
EXIT
B
ADV--------------------
choose device
To return to the Main
screen at any time:
FX
CC
DC
MATE
MAIN-------------------
SUM STATUS SETUP ADV
Press and hold the 2 left
soft keys at the same time.
Release when the Main
screen appears.
900-0131-01-00 Rev A.vsd\CC Setup on MATE\2012-03-21
©2012 OutBack Power Technologies. All Rights Reserved.
Advanced Menu for the
FLEXmax Charge Controller
(Page 1 of 2)
ADV/CC/PAGE1
choose category
ADV
CHGR CCADV
PG2
ADV/CC/ADVANCED------P02
ADV/CC/CHGR----------P02
snooze mode
output current
80.0 A
<0.6 AMP
limit
DOWN
INC
DEC
PORT
DOWN
INC
ADV/CC/ADVANCED------P02
ADV/CC/CHRG----------P02
absorb voltage
28.8 V
wakeup mode
VOC change
DOWN
INC
DOWN
INC
DEC
PORT
ADV/CC/CHRG----------P02
ADV/CC/ADVANCED------P02
wakeup mode
float voltage
27.2 V
time 5 minutes
DOWN
INC
DOWN
INC
DEC
PORT
ADV/CC/ADVANCED------P02
ADV/FX/CHRG----------P02
MPPT mode
end charger menu
auto track
DOWN
INC
TOP
ADV
MAIN
ADV/CC/ADVANCED------P02
grid tie mode
nonGT
DOWN
INC
ADV/CC/ADVANCED------P02
park MPP 77.0%
3:02:14P
DOWN
INC
ADV/CC/ADVANCED------P02
ADV/CC/ADVANCED------P02
Mpp range limit %VOC
RTS compensation
maximum 90%
DEC
PORT
DOWN
INC
DEC
PORT
DOWN
ADV/CC/ADVANCED------P02
ADV/CC/ADVANCED------P02
MPP range limit % VOC
RTS comp limit
3.0 V
minimum 1/2
upper limit 28.2 Vdc
DEC
PORT
DOWN
INC
DEC
PORT
DOWN
ADV/CC/ADVANCED------P02
ADV/CC/ADVANCED------P02
absorb time
RTS comp limit
1.0 hours
lower limit 26.4 Vdc
DEC
PORT
DOWN
INC
DEC
PORT
DOWN
ADV/CC/ADVANCED------P02
ADV/CC/ADVANCED------P02
absorb end amps
auto restart
0A
DEC
PORT
DOWN
INC
DEC
PORT
DOWN
ADV/CC/ADVANCED------P02
ADV/CC/ADVANCED------P02
rebulk voltage
AUX output polarity
24.8 Vdc
DEC
PORT
DOWN
INC
DEC
PORT
DOWN
ADV/CC/ADVANCED------P02
ADV/CC/ADVANCED------P02
vbatt calibration
Reset CC to factory
29.3 Vdc
0.0 Vdc
DEC
PORT
DOWN
INC
DEC
PORT
DOWN
ADV/CC/ADVANCED------P02
end CC advanced menu
Advanced Menu for the
FLEXmax Charge Controller
(Page 2 of 2)
ADV/CC/PAGE2---------P02
choose category
PG1
ADV/CC/EQ------------P02
eq voltage 28.8 VOC
wide
INC
DEC
PORT
DOWN
INC SETUP ADV
ADV/CC/EQ------------P02
eq time 1 hours
INC
DEC
PORT
DOWN
INC SETUP ADV
ADV/CC/EQ------------P02
eq auto eq interval
0 days
INC
DEC
PORT
DOWN
INC SETUP
ADV
ADV/CC/EQ------------P02
end CC eq menu
mode 0
INC
DEC
PORT
TOP
ADV
MAIN
active
INC
DEC
PORT
defaults?
YES
NO
PORT
MAIN--------------------
TOP
ADV
MAIN
EQ
AUX
MAIN
ADV/CC/AUX-----------P02
vent fan
DOWN
INC
SET
PORT
ADV/CC/AUX-----------P02
aux control
OFF
DOWN
ON
OFF
PORT
ADV/CC/aux-----------P02
end of menu
TOP
ADV
MAIN
3:02:14P
SUM STATUS SETUP ADV
Page 8