Epever LandStar BPL Series Короткий посібник - Сторінка 2

Переглянути онлайн або завантажити pdf Короткий посібник для Контролер Epever LandStar BPL Series. Epever LandStar BPL Series 2 сторінки. Solar charge controller with built in led driver
Також для Epever LandStar BPL Series: Посібник із швидкого старту (2 сторінок)

Epever LandStar BPL Series Короткий посібник
NOTE:The load is ON when the controller power on 1seconds. After 1
seconds it will restore to set working mode.
NOTE: In the mode of Light ON/OFF and Light ON/Timer, the Load is
turned on after 1Min. delay.
7. Accessories(optional) and Software
1)PC Software
www.epever.com ——Solar Station Monitor
2)APP Software
 Android phone
www.epever.com——ChargeController(Sealed)
 IPhone
APP Store——EPEVER——EP-01
※Specific instructions refer to the list of accessories and software.
8. Protection
 PV Short Circuit
 If the PV array short circuit, the controller will stop charging, clear it to resume normal
operation.
 PV Reverse Polarity
 Fully protection against PV reverse polarity, correct the wire connection to resume
normal operation.
 Battery Reverse Polarity
 Fully protection against battery reverse polarity, correct the wire connection to
resume normal operation.
 Battery Over Voltage
 When the battery voltage reaches to the set point of Over Voltage Disconnect Voltage,
the controller will stop charging the battery to protect the battery from being over
charged to break down.
 Battery Over Discharge
When the battery voltage reaches to the set point of Low Voltage Disconnect Voltage,
the controller will stop discharging the battery to protect the battery from being over
discharged to break down.
 Battery Overheating
 The controller detect the environment temperature through the external temperature
sensor. If the environment temperature exceeds 65 º C, the controller will
automatically start the overheating protection to stop working, and recover below
50 º C.
 Load Short Circuit
 Load will be switched off when load short circuit (≥4 times rated current) happens.
Controller will automatically attempt to reconnect load for 5 times. If short circuit
protection still exist after controller's 5 times attempts, user have to clear short
circuit ,then restart the controller or wait for one night-day cycle (night time>3 hours).
 Controller Overheating
 If the temperature of the controller exceeds 85 º C, the controller will automatically
start the overheating protection, and recover below 75 º C.
 High Voltage Transients
 The controller is protected against small high voltage transients. In lightning prone
areas, additional external suppression is recommended.
9. Troubleshooting
Faults
Possible reasons
LED Charging
indicator turn off
during daytime
PV
when sunshine falls
array disconnection
on PV modules
properly
Battery voltage maybe
No LED indicator
less than 9V
Battery LED
indicator green fast
Battery over voltage
Flashing
Battery LED
Battery
indicator red
over discharged
Battery LED
indicator red
Battery Overheating
flashing
Controller overheating
Charging(green)
and battery
indicator
(orange)flashing
System voltage error
simultaneously
①The connecting
Powering on
normally, the load is
wires are error or
off
virtually connected
BEIJING EPSOLAR TECHNOLOGY CO., LTD.
Troubleshooting
Confirm that PV and battery wire
connections are correct and tight
Measure battery voltage with the
multi-meter. Min.9V can start up the
controller
Check if battery voltage is higher
than OVD, and disconnect the PV
When the battery voltage is restored
to or above LVR point (low voltage
reconnect voltage), the load will
recover
The controller will automatically turn
the system off. But while the
temperature decline to be below 50
º C, the controller will resume.
please try to decline the
environment's temperature, or the
power of PV or the power of the load
Check whether the battery voltage
match with the controller's working
voltage, If not please change to a
suitable battery or reset the working
voltage
①Check the connecting cable.
②Check the load's mode and
parameters.
3
Tel:+86-10-82894112 / 82894962 Website:www.epsolarpv.com/www.epever.com
②Load mode is not
appropriate.
③This controller does
not match with the LED
light.
④Output short circuit.
The controller does not
match with the LED
light source. This
The dimming
product is a step-up
function is invalid
voltage control, If input
voltage is lower than
the rated voltage, it is
not working.
10. Technical Specifications
Item
Nominal system voltage
Battery input voltage range
Max. PV open circuit voltage
Rated charge current
Max. output current
Max. output power
Output voltage range
Load open circuit voltage
Max. output efficiency
Output current control
accuracy
Battery Type
Self-consumption
Charge Circuit Voltage Drop
Temperature compensation
coefficient
Working environment
temperature
Enclosure
Grounding
Overall dimension
Mounting dimension
Mounting hole size
PV/BAT: 14AWG(2.5mm
Power cable
LOAD: 18AWG(1.0mm
Net weight
Battery Voltage Control Parameters (below parameters are in 12V system at 25 º C,
please double the values in 24V system)
Battery Type Select
Over Voltage Disconnect Voltage
Charging Limit Voltage
Over Voltage Reconnect Voltage
Equalize Charging Voltage
Boost Charging Voltage
Float Charging Voltage
Boost Reconnect Charging Voltage
Low Voltage Reconnect Voltage
Under Voltage Warning Reconnect
Voltage
Under Voltage Warning Voltage
Low Voltage Disconnect Voltage
Discharging Limit Voltage
Equalize Duration
Boost Duration
NOTE:
1) The default battery type is Sealed, For Sealed, Gel, Flooded battery type, the
voltage point is fixed, unable to be modified. The adjusting range of equalize
duration is 0 to180min and boost duration is 10 to180min.
2) User type is the user defined battery type. The default value is the same as
sealed type. When modify it, please follow the below logistic relation:
a ) Over Voltage Disconnect Voltage>Charging Limit Voltage ≥Equalize Charging
Voltage ≥Boost Charging Voltage ≥ Float Charging Voltage >Boost Reconnect
Charging Voltage.
b ) Over Voltage Disconnect Voltage>Over Voltage Reconnect Voltage.
c) Low Voltage Reconnect Voltage>Low Voltage Disconnect Voltage ≥ Discharging
Limit Voltage.
d ) Under Voltage Warning Reconnect Voltage>Under Voltage Warning Voltage ≥
Discharging Limit Voltage.
e ) Boost Reconnect Charging voltage>Low Voltage Disconnect Voltage.
11. Disclaimer
This warranty does not apply under the following conditions:
 Damage from improper use or use in an unsuitable environment.
 PV or load current, voltage or power exceeding the rated value of controller.
 The controller is working temperature exceed the limit working environment
temperature.
 User disassembly or attempted repair the controller without permission.
 The controller is damaged due to natural elements such as lighting.
 The controller is damaged during transportation and shipment.
Any changes without prior notice! Version number:V3.1
③The voltage of LED light is not
within the output voltage range of
controller.
④Check the connecting cables and
LED light.
①Replace the LED light
②Reduce system rated voltage
grade and replace the product
model
For example 24V system change to
12V system, and replace the
corresponding controller
LS102460BPL
LS2024100BPL
12/24VDC Auto
9V~32V
50V
10A
20A
2.0A
3.3A
30W/12V;60W/24V
50W/12V;100W/24V
Max. battery voltage+2V~60V
60V
96.7%
≤30mA
Sealed(default)/Gel/Flooded/User
≤11mA/12V;≤9mA/24V
≤0.3V
-3mV/℃/2V
-35℃~+55℃
IP67
Common Positive
107x73x20mm
108.5x102x25.6mm
100mm
100.5x80mm
Φ4
Φ5
2
)
PV/BAT:12AWG(4.0mm
2
)
LOAD: 18AWG(1.0mm
0.28kg
0.46kg
Sealed
Gel
Flooded
16.0V
16.0V
16.0V
15.0V
15.0V
15.0V
15.0V
15.0V
15.0V
——
14.6V
14.8V
14.4V
14.2V
14.6V
13.8V
13.8V
13.8V
13.2V
13.2V
13.2V
12.6V
12.6V
12.6V
12.2V
12.2V
12.2V
12.0V
12.0V
12.0V
11.1V
11.1V
11.1V
10.6V
10.6V
10.6V
——
120 min
120 min
120 min
120 min
120 min
4
2
)
2
)
User
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
0~180 min
10~180 min