EPH R17-RF Інструкція з монтажу - Сторінка 2
Переглянути онлайн або завантажити pdf Інструкція з монтажу для Таймер EPH R17-RF. EPH R17-RF 2 сторінки. 1 zone rf timeswitch
R17-RF - 1 Zone RF Timeswitch
Contents
1.
Factory default settings
2.
Speci cations & wiring
3.
Setting the date & time
4.
Frost protection
5.
Master reset
1. Factory default settings
Contacts:
Volt free contact
Program:
5/2D
Backlight:
On
Keypad:
Unlocked
Frost Protection:
O
Clock type:
24 Hr Clock
Day-Light Saving
2. Speci cations & wiring
Power Supply:
230 Vac
Ambient Temp:
0~35°C
Contact Rating:
250 Vac 3A(1A)
Program Memory
backup:
1 year
Battery:
3Vdc Lithium LIR 2032
Backlight:
Blue
IP rating:
IP20
Backplate:
British System Standard
Pollution degree 2:
Resistance to voltage surge 2000V
as per EN 60730
Automatic Action:
Type 1.S
Software:
Class A
COM
200-240Vac
50Hz-60Hz
If mains voltage output is required, terminals L & 1 must be electrically
linked. The cable link is provided with this timeswitch.
OFF
ON
CONTACT RATING: 250Vac~/3(1)A
EPH Controls Ireland
Sitecast Industrial Estate, Pouladu ,
Cork, T12 W665, Ireland
[email protected] www.ephcontrols.com
Page 2 of 2
Installation Instructions
For use in normal environments.
3. Setting the date and time
Lower the cover on the front of the timeswitch.
Move the selector switch to the CLOCK SET position.
Press the
or
buttons to select the day.
Press the
or
buttons to select the month.
Press the
or
buttons to select the year.
Press the
or
buttons to select the hour.
Press the
or
buttons to select the minute.
Press the
or
buttons to select 5/2D, 7D or 24H
The date, time and function are now set.
Move the selector switch to the RUN position to run the program, or to
the PROG SET position to change the program setting.
4. Frost protection function
Selectable range 5~20°C
This function is set to protect pipes against freezing or to prevent low room
temperature when the timeswitch is programmed to be OFF or is manually
OFF.
Frost protection can be activated by following the procedure below.
Move the selector switch to the RUN position.
Press both the
and
buttons for 5 seconds, to enter selection mode.
Press either the
or
buttons to to turn On or turn O frost protection.
Press
button to con rm
Press either the
or
buttons to increase or decrease the desired frost
protection setpoint.
Press
to select.
Zone 1 will be switched ON in the event of room temperature falling below
the frost protection setpoint.
5. Master reset
Lower the cover on the front of the timeswitch. There are four hinges
holding the cover in place.
Between the 3rd and 4th hinges there is a circular hole. Insert a ball point
pen or similar object to master reset the timeswitch.
After pressing the master reset button, the date and time will now need to
be reprogrammed.
EPH Controls UK
Unit E4, Welland Business Park, Valley Way, Market Harborough,
Leicestershire, LE16 7PS, United Kingdom
[email protected] www.ephcontrols.co.uk