DieHard 200.713201 Посібник користувача - Сторінка 12
Переглянути онлайн або завантажити pdf Посібник користувача для Зарядний пристрій DieHard 200.713201. DieHard 200.713201 16 сторінок. 20/15/10/2 amp fully automatic battery charger
Також для DieHard 200.713201: Посібник користувача (16 сторінок)
Charge Time Needed if Amp-Hours is Known
• Find the Charge Factor for your battery in the table on page 11.
• Multiply by the Amp-Hour rating of the battery.
• Divide by the Charger Setting (either 2 Amp, 10 Amp or 20 Amp).
• Multiply by 1.25 to get the approximate Hours Needed to bring the battery to full
charge.
Example: 15 Amp-Hour (AH) Battery, 50% State-of-Charge,
[(AH x Charge Factor) ÷ Charger Setting] x 1.25 = Hours Needed
(15 x 0.5 ÷ 2) x 1.25 = 4.7 Hours
Charge Time Needed if Reserve Capacity is Known
• Find the Charge Factor for your battery in the table on page 11.
• Multiply by the Reserve Capacity rating of the battery.
• Divide by the Charger Setting (either 2 Amp, 10 Amp or 20 Amp).
• Multiply by 0.73 to get the approximate Hours Needed to bring the battery to
full charge.
Example: 95-Minute Reserve Capacity (RC) Battery, 25%
[(RC x Charge Factor) ÷ Charger Setting] x 0.73 = Hours Needed
[(95 x 0.75) ÷ 20] x 0.73 = 2.6 Hours
To keep your battery charger working properly for years:
1. Clean the clamps each time you are
finished charging. Wipe off any
battery fluid that may have
come in contact with the clamps to
prevent corrosion.
2 Amp Charger Setting
State-of-Charge, 20 Amp Charger Setting
MAINTENANCE AND CARE
2. Coil the input and output cords
neatly when storing the charger.
This will help prevent accidental
damage to the cords and charger.
12