2 Switch – 2 Way Operation
Note, current machnical switch must be compatible for 2 way operations.
1. Remove current Live-in AC 230V wire & Neutral-in AC 230V wires from the
existing wall
2. Mechanical Switch 1A / 1B and 2A / 2B must already be connected into 'L1 &
L2' terminal.
3. Connect Live-in AC 230V wire & Neutral-in AC 230V wires into module
terminal 'L & N'.
4. Connect wire from module terminal 'S1' into mechanical switch 1A 'Com'
terminal.
5. Connect Live-in AC 230V wire into mechanical switch 1B 'Com' terminal.
6. Connect wire from module terminal 'S2' into mechanical switch 2A 'Com'
terminal.
7. Connect Live-in AC 230V wire into mechanical switch 2B 'Com' terminal.
8. Connect output load into 'O1 & O2' terminal.
INSTALLATION - WIRING
6