Getting started
Power supply
Operating power for ARC600 is supplied through the
connector X2.1. ARC600 can use either AC line input
(pins 1 and 2) or DC input (pins 6 and 7).
In some situations, the device does not boot
directly from a DC voltage. In this case, you should
apply the AC voltage for a moment (devices' deep discharge
protection reset) after which you can connect the
DC supply voltage as usual.
Power-up and SIM card installation
Insert the SIM card. Push the yellow button in the SIM card
slot to eject the SIM card tray. Insert the SIM card to the
tray (contacts facing up) and push it firmly and carefully
back to its holder. Attach the power supply and switch the
device on. Under normal circumstances, the device is able
to automatically connect to the operator's cellular network.
In problem situations you can log in to the Arctic Web user
interface by using a Web browser and navigating to
Network → Mobile
WAN.
If your SIM card requires a PIN code, do not install
it before you have configured the Arctic device
PIN code settings.
—
Figure 1. Browser https example
Login to the Arctic Web user interface
Connect the Ethernet cable between the Arctic device
LAN port and your computer.
Configure your computer to use the same IP address space
as the Arctic device. For example, your computer IP could
be 10.10.10.11 with netmask 255.255.255.0. Check the
connection with the ping command.
Connect to the Arctic device using the web browser.
The default address of the Arctic device is https://10.10.10.10/.
https
Remember to use
and not http.
Accept the self-signed certificate in the browser.
Log in to the device. The username is
default password is arcticm2m.
It is highly recommended that the default
is changed
before the product is connected to a public
cellular network.
—
Figure 2. Welcome page in the ARC600 Web user interface
arctic-adm
and the