Examples of configuration messages are as follows :
#1#Alarm Gas#T#+44123456789123#
#2#Gate Intrusion #S#+445678925567#+44567894567899#
#3#Water ON#T#+4467895657488#+4473263748596#+445476576879888#
After sending this message the receiving Archimedes Pwr LED will flash for 5 secs to
indicate the message has been received and stored.
A few moments after the alarm LED's will turn off to indicate those alarms have been
configured.
If any of the alarms have been configured previously they will turn on briefly and then turn
off when they have been reconfigured..
In the case that the Archimede SMS receives a message (Pwr LED flashes) but alarm
LED's stay on check the SMS message for any Syntax errors.
3.1.3 Alarm Configuration for Interuption of Power
In the event of power failure the Archimede SMS uses its internal battery to send a
message in order to inform users that a power failure has occurred.
After sending the message the Archimedes switches off to conserve the battery.
On return of the power the Archimedes sends a message informing the return of power
and recommences to check the status of alarm and report accordingly.
As an additional security measure the small battery inside the Archimedes is checked
regularly for charge and a message if the charge is below 8VDC. Under normal
circumstances the battery should last for a period of about 12 months before changing.
After the insertion of a new battery the unit should be reset by sending the following SMS
message to the Archimede SIM number.
# 9 # Message
Field
#
9
#
Message
#
No Tel 1
#
No Tel 2
#
No Tel 3
#
• Note * The telephone number must always be inserted with its international code ie
+44 for UK, +49 for Germany , +33 for France etc
• All SMS messages must end with a # sign
# Tel 1 # Tel 2 # Tel 3
Quantiy Characters
1
1
1
Max 20
1
20 Max
1
20 Max
1
20 Max
1
#
Description
Delimit Character
9 is the memory location for Power Loss
Delimit Character
Message to be sent to identify Power Alarm
Delimit Character
First Tel Number to send the Pwr Alarm
Message
Delimit Character
Second Tel Number to send the Pwr Alarm
Message
Delimit Character
Third Number to send the Pwr Alarm Message
Delimit Character
11