Aybey Elektronik ALYA Посібник з монтажу - Сторінка 4
Переглянути онлайн або завантажити pdf Посібник з монтажу для Системи управління Aybey Elektronik ALYA. Aybey Elektronik ALYA 5 сторінок. Serial communication duplex lop
3- Operation and Adjustment Operations
There are 4 programming buttons on the board: UP, DOWN and ENT-R/L. You can
increase the value of a parameter by pressing UP and decrease it by pressing DOWN
button. The ENT-L button allows making changes to the left display, and the ENT-R
button to the right display. After setting it to the desired value, press ENT button shortly
to confirm.
Press the ENT button for 3 seconds to enter the setting menu of the right or left indicator,
whichever is to be adjusted.
You will see the floor number of the LOP (which is called as its ID) and the characters "ıd"
flashing sequentially. Here "ıd" represents the parameter name and the number is its
value. You can increase the floor number by pressing UP button and decrease it by pressing
DOWN button. Only the floor number is displayed while one is pressing UP or DOWN
buttons. When no button is being pressed then again "ıd" and floor number will be flashed
sequentially.
When you have adjusted all parameters then press the same ENT button 3 secs to save
the parameters and exit from menu.
Parameter
Code
ıd
bL
SM
SF
Range
Definition
Floor Number of LOP
0...63
Buzzer Level.
Increasing value makes the buzzer volume to decrease, where 1
0...9
is the loudest value.
Zero value disables buzzer.
0-Lift Operation Mode
0,1
1-Simulation Mode where LOP stops communication and
displays numbers in the range of 0 to Simulation Floor.
Maximum displayed Floor Number in simulation mode.
0...63
3